9
INSTALLATION (Part 2 of 5)
)
Interim Inspection
Verify/Perform the following:
1.
Ensure loading door(s) open/close freely past 90
o
without obstruction.
2.
Remove all packing materials from inside oven.
3.
Remove carousel wheel shipping ties at carousel support hub (left wall) and drive arm (right wall).
4.
Remove clear protective plastic covering from data plate and 15A fuse “Caution” plate.
Water Drain Connection
Locate the 1” hose barb fittings on the valve underneath the oven. (NOTE: There are two fittings; the water fitting is on
the right as you face the backside of the oven.) Connect a 1” diameter PVC hose to the water fitting and secure with the
band clamp provided. Route the hose to an air-gap floor drain.
Water
Drain
Oven Body
(Rear View)
Grease Drain Connection
Locate the 1” hose barb fittings on the valve underneath the oven. (NOTE: There are two fittings; the grease drain fitting
is on the left as you face the backside of the oven.) Connect a 1” diameter PVC hose to the grease fitting and secure with
the band clamp provided. Route the hose to a grease receptacle.
Oven Body
(Rear View)
Grease
Drain