This parameter allows to you to select the functionality of the
Field Muted
button in press
brake operation.
WARNING: NO PROTECTION IN FIELD MUTED MODE
In Field Muted mode, the optical sensing is deactivated. Although the LZS-003-HS
ensures that the machine does not exceed crawl speed in this mode, particular
caution must still be exercised.
The LZS-003-HS Operator Panel requires a password to enable the Field Muted
mode button. The password should only be available to suitably trained personnel.
Field Muted mode should only be used by suitably trained personnel and only
in exceptional circumstances (changing tools, maintenance, etc.)
The three options available are:
Option
Functionality
Enabled
The button is enabled and the operator can enter Field Muted mode at any
time.
Disabled-On
The button is disabled and the system is locked into Field Muted mode.
Disabled-Off
The button is disabled and the system is locked out of Field Muted mode.
On entering this parameter's menu, the display shows:
Figure 7-12: Field Muted button functionality - option 1
Pressing the
Guard Mode
button successively displays the other options for this parameter.
Press
SET
to accept your selection.
If you go past the option you wish to set, press the
Field Muted
button to move "up" a menu
item.