![Lazer Safe LZS-003-HS Operation Manual Download Page 19](http://html1.mh-extra.com/html/lazer-safe/lzs-003-hs/lzs-003-hs_operation-manual_3989581019.webp)
LS-CS-M0005-EN
LZS-003-HS Operation Manual – Dual Laser Version
Page 13
Version 1.11
Released: 03/12/2007
5.1.2
LZS-003-HS Controller
The
LZS-003-HS Controller
is usually mounted on the side of the press brake. It has a two
digit LED display that also provides important status information on the operation of the LZS-
003-HS. The left-hand digit is referred to as the
Secondary Digit
and the right-hand digit as
the
Primary Digit
. The LZS-003-HS Controller is shown in Figure 5-2:
Figure 5-2: LZS-003-HS Controller
Note:
Section 8 contains detailed information on error codes.
5
5
.
.
2
2
S
S
y
y
s
s
t
t
e
e
m
m
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
When the LZS-003-HS system is powered-up the controller will perform a self test. During the
self test the LCD Operator Panel will display software version information and the controller will
cycle various numbers on the two segment display. After the self test is complete the controller
display will show 01 and the LCD Operator panel display will scroll the LZS-003-HS system
software version and laser to punch distance setting across the top line of the display.
The laser to punch distance setting will be displayed as 14mm. Check that the laser is aligned
14mm below the punch.
Note:
Refer to Section 4 or the Transmitter and Receiver Alignment Manual for detailed
information regarding alignment and laser to punch settings.
Once the laser to punch distance has been checked press the SET button as indicated on the
LCD Operator Panel display. Proceed with the Start-up test.