LS-CS-M0005-EN
LZS-003-HS Operation Manual – Dual Laser Version
Page 5
Version 1.11
Released: 03/12/2007
Mute point
Laser to punch
distance
Laser A 4mm
Laser B 14mm
Figure 3-1: LZS-003-HS Dual Laser
3.2.2
Setup
During setup the laser is set at a distance of 14mm below the tip of the punch. When using the
LZS-003-HS dual laser only the lower laser (Laser B) is switched on during set-up.
Mute point
2mm
Laser B to
punch distance
14mm
Figure 3-2: Laser to punch distance / Mute point distance
3.2.3
Mute Point
The Mute point must first be established so that the LZS-003-HS will not treat the material
being formed as an obstruction. The Mute point is automatically set at 2.0mm above the
surface of the material as the tools close for the first stroke. This mute point set-up can be
initiated whenever the material thickness is substantially changed.