III. OPERATION
1. OPERATING CHECKLIST
OPERATING LOCATION
Only use this generator OUTSIDE and in well
ventilated areas.
Only operate the generator on a flat, level surface and
in a clean, dry operating environments. Only use the
generator for applications within its operating scope.
If you have any question regarding applicable scope,
please speak to your nearest Service Agent.
In some locations and regions, the generator may
require additional provisions and or regulations for
operation, please consult with your nearest Service
Agent.
DANGER
TOXIC FUMES
The exhaust of the generator contains carbon
monoxide, using the engine indoors may cause
serious personal injury including death. DO NOT use
the generator inside any buildings or within enclosed
spaces EVEN IF doors and windows are open. Place
the generator in a well-ventilated and clean area.
Note the wind direction and airflow when placing the
generator.
HIGH ALTITUDE
This generator may require a high altitude carburetor
kit to ensure correct operation at high altitudes.
Consult with your local authorised dealer for high
altitude kit information if you intend to operate
the generator at altitudes above 5, 000 feet (1,500
meters).
CAUTION
•
Even with carburetor modification, generator
horsepower will decrease by 3.5% for every
1,000 feet (300 meters) increase in altitude.
The effect of altitude on horsepower will be
greater than this if no carburetor modification
is made.
•
Operating the engine at altitudes below 5, 000
feet (1,500 meters) with a modified carburetor
may cause the generator to overheat and result
in serious engine damage. Please restore
factory specifications of the carburetor with
your service dealer when using the engine in
low altitude areas.
2. OPERATING CONDITION
Check for loose or damaged parts, signs of oil or fuel
leaks, and any other condition that may affect proper
operation. Repair and or replace with genuine spare
parts immediately.
WARNING
•
Failure to correct problem(s) before operation
may result in property damage and or serious
personal injury.
•
Remove excessive dirt or debris, especially
around the muffler and recoil starter.
•
DO NOT move or tip the generator during
operation.
3. ENGINE OIL
•
Place the engine on a level surface with engine
stopped. Check the engine oil level.
•
Remove the oil maintenance cover.
•
Remove the dipstick and wipe it clean.
•
Reinstall dipstick into hole; rest on oil fill neck,
DO NOT thread cap into hole.
•
Remove the dipstick again and check oil level.
Level should be between the upper and lower
limit.
•
Fill to the upper limit of the dipstick with the
recommended oil if the oil level is too low.