COMBINATION SWITCH
(STOP & OFF & RUN & CHOKE)
Note: One-button start and remote control start have
auto chokes.
Stop: Switch to turn the generator off.
Note: After the generator is unloaded, please run for
3 minutes with no load to stabilize the temperature,
then stop the generator.
Off: Fuel shut off valve. This position can run out of
the remaining fuel to ensure old fuel is not present
when generator has not been used for long periods.
Note: If you do not plan to use the generator in the
near future, please use this function, or drain the
fuel inside the carburettor using the drain bolt on the
carburettor bowl.
Run: The generator operates normally.
Choke: Close the choke.
Note: Turn to choke position to start when engine is
cold, and turn to Run position to start when engine
is hot.
CIRCUIT BREAKER
When the generator is overloaded or has overheated,
the thermal protection works. Please reduce the
load, or run it for a few minutes without load. Press
the circuit breaker button to restore output power to
equipment.
Note: The circuit breaker is influenced by factors,
such as operation current and ambient temperature,
so the protection time varies.
PARALLEL KIT TERMINAL
It is used for parallel operation with another inverter
(parallel kit sold separately).
FUEL TANK CAP
Remove the fuel tank cap by rotating it anticlock-
wise.
VENTILATION KNOB (IF APPLICABLE)
The fuel cap is equipped with a ventilation knob
to prevent fuel leakage. During operation, the
ventilation knob must be in the “ON” position for the
generator to operate normally. When the genera-
tor will not be use for a long time or needs to be
transported, turn the ventilation knob to the “OFF”
position to prevent fuel leakage.
TELESCOPING HANDLE
When moving the generator, please hold the tele-
scoping handle and press the button on it, and pull
it outward.
Note: Before moving, please turn off the generator
and fuel switch. Please move the generator on a
relatively flat ground. Do not perform the movement
on a surface where the pit exceeds 40mm.