6
A STEELFORT PRODUCT | STEELFORT.CO.NZ
OVERLOAD INDICATOR (RED)
When the overload indicator is on, it indicates that
the generating set is overloaded and then the AC
circuit breaker has tripped. It will stop the power
output of generating set to protect the electric
equipment and the generator set itself. At this time,
the running indicator (green) is off and the overload
indicator (red) is on, but the engine is still in running
state.
When the generating set has no output and the
overload indicator is on, please take the following
steps:
1. Lower the total load of the connected electric
devices to the rated output range of the
generator.
2.
Check the air filter to ensure it is not clocked
and the generator is in an open area to allow
enough air flow to the generator.
3. Press the reset button.
RUNNING INDICATOR (GREEN)
The running indicator lights up when generating set
starts and has normal output.
OIL ALARM LAMP (YELLOW)
When the oil level drops below the lower limit, the oil
protection system will stop the engine automatically
and oil alarming lamp will blink when recoil starter is
pulled. The engine will not run until the oil has been
filled to the proper level.
Note: If engine stalls or fails to start, turn the
combination switch to “RUN” position and then pull
the recoil starter. If the oil alarming lamp lights up,
it shows lack of oil. Please add appropriate oil and
restart the engine.
RESET BUTTON
The reset button is used to restore output if an
overload occurs. To restore output, reduce the
load(s) and press the reset button.
ENERGY-SAVING SWITCH
When the energy-saving switch is in “ON” position,
the energy saving equipment controls the engine
rpm according to the connected loads. There will
be good fuel consumption and low noise. When the
energy-saving switch is in “OFF” position, the engine
will always run at full rpm no matter what load is
connected to it.
Note: Please set the energy-saving switch to “OFF”
position when connect to an air compressor, pumps,
circular saws etc., Due to large starting current
required.
GROUNDING TERMINAL
The grounding terminal is designed to prevent
electric shock by connecting it to the grounding wire.
The generating set must be properly grounded before
operation.