background image

Model: 2200

I

Inverter Generator

OPERATOR’S MANUAL

SAVE THIS MANUAL FOR FUTURE REFERENCE

This manual contains important information regarding safety, operation, and maintenance.  

CPO Commerce, LLC

60 Crestridge DR

Suwanee, GA  30024

Customer

 service#: 1-866-577-3014

EMAIL: [email protected]

Summary of Contents for 2200I

Page 1: ...L SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety operation and maintenance CPO Commerce LLC 60 Crestridge DR Suwanee GA 30024 Customer service 1 866...

Page 2: ...erator to an Electrical System 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 Charging a...

Page 3: ...ine equipment complies with exhaust and evaporative emissions stan dards Locate the emissions compliance decal on the engine to determine applicable stan dards For emissions warranty information pleas...

Page 4: ...esult in serious injury or death WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigu...

Page 5: ...spark plug wire and make sure the fuel tank is empty with the 3 in 1 switch is turned to the off position WARNING Never exceed generators wattage amperage capacity This could damage the generator and...

Page 6: ...ord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a ground fault circuit interrupter GF...

Page 7: ...el E Handle Grip F Air Vent G Fuel Cap H Recoil Starter N S O P Q I Control Panel J Oil Warning Light K Overload Indicator Light L AC Pilot Light M 3 in 1 Start Switch RUN OFF and Choke N Economy Swit...

Page 8: ...arter Engine Overload Indicator Light If the engine overload indicator light comes on the generator s wattage amperage capacity has been exceeded by connected electrical devices or by a power surge Wh...

Page 9: ...ngine ECO Control When the Engine ECO switch is turned to the ON position the economy control unit automatically determines the generator s proper engine speed based on the connected electronic load T...

Page 10: ...onnect the generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gage copper wire The wire connects to the terminal between the lock washe...

Page 11: ...ator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System If connecting generator to a building s elect...

Page 12: ...nd securely tighten before attempting to start the engine Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir un...

Page 13: ...o the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as engin...

Page 14: ...Turn the Air Vent to the OFF position How to Attach Electronic Devices 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is withi...

Page 15: ...ck the gravity level of the electrode at least once per hour with a hydrometer to prevent overcharging and to test the battery s condition Be careful to follow the hydrometer manufacture s instruction...

Page 16: ...ARNING A faulty appliance or power cord can create an electric shock Do not use electronic devices that have a damaged cord or plug If an appliance begins to operate abnormally becomes sluggish or sta...

Page 17: ...Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Wattage Reference Guide Wattages listed are just approximations Check electronic device for actual wattage Don t Overload Generator Make sure you...

Page 18: ...ose debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry are...

Page 19: ...a wire brush Check the electrode gap and slowly adjust to 0 7 0 8mm 0 028 0 031 in if necessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft lb If spark plug is worn replace only with an e...

Page 20: ...generator to collect used oil Allow oil to drain completely Return generator to a level surface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall...

Page 21: ...ment should be damp but not dripping Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result CAUTION Remove screws then remove shown area of out...

Page 22: ...s Remove any debris if obstructed Store indoors and use a protective cover to protect from dust FUEL For short term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits...

Page 23: ...ngine and let it run until it stops and all remaining fuel is consumed Do not connect electronic devices to generator during this process Remove outer casing screws then remove outer casing Turn the 3...

Page 24: ...ct service department 5 Contact service department Engine will not start shuts down during operation or starts and runs rough 1 3 in 1 switch set to OFF 4 Out of fuel or Stale fuel 5 Spark plug wire d...

Page 25: ...Overload Protect DC Non Fuse Protector AC Frequency Regulator Overload Protection Process Control Engine Engine DH80i Engine Type Single Cylinder 4 Stroke Forced Air Cooling OHV Displacement 80cc Fue...

Page 26: ...26 WIRING DIAGRAM W W P 2 1 3 4 03 017 1...

Reviews: