![LAVOR Pro GV 3,3 M PLUS Manual Download Page 66](http://html1.mh-extra.com/html/lavor-pro/gv-3-3-m-plus/gv-3-3-m-plus_manual_3928451066.webp)
Troubleshooting
Please find below a list of all the possible troubles that may occur on the machine.
CAUSES
SOLUTIONS
- Resistance
contactor
- Pressure switch
- Resistance
- Thermal resistance
- PT100 Thermal
resistance
- The water tank is
empty
- Pump
- Pump
- Lack of water in
the tank
- water solenoid valve
- Check the
electronic level
- Water level probe
- Boiler water level
probe
- Check the
electronic level
- Pressure switch
- Resistance
contactor
- Safety valve
- C h e c k t h e r e s i s t a n c e
contactor
- Check the pressure switch
- Check the resistance
- Check that the temperature
is at least 133
°
C
- Check
- Fill the tank
- Replace the pump
- Replace the pump
- Fill the tank
- Replace the solenoid valve
- Check and eventually replace
it
- Clean the probe
- Clean the probe
- Replace it
- Replace the pressure switch
a n d c h e c k t h a t t h e
connection copper tube is
f r e e f r o m i n c r u s t a t i o n s .
- Replace the resistance
contactor
- Replace the safety valve
TROUBLES
THE GENERATOR
PRESSURE DOES
NOT INCREASE
T H E P U M P
C A N N O T R U N
2.1 It loads no
water
2.2 The red light is
on
2.3 It does not run
T H E S A F E T Y
VA LV E O P E N S
R E P E A T E D L Y
3.1 It keeps on
loading water
1
2
3