![LAVOR Pro GV 3,3 M PLUS Manual Download Page 14](http://html1.mh-extra.com/html/lavor-pro/gv-3-3-m-plus/gv-3-3-m-plus_manual_3928451014.webp)
13
USER’S INSTRUCTIONS
TECHNICAL CHARACTERISTICS
• Supply: 230V 50/60Hz; 400V 50Hz (low voltage handle, 18V)
• Installed power: 3300W; 4400W
• Boiler capacity: 3,6 litres
• Water tank capacity: 5 litres
• Boiler water supply system: continuous automatic pump
• Steam pressure: 9 bar
• Steam temperature in boiler: max. 175
°
C
• Measurements in cm: M (62 x 40 x 86) ; VAC (60 x 40 x 93)
• Empty weight: M (37 Kg) ; VAC (43 Kg)
• Weight with accessories: M (39 Kg) ; VAC (46)
ADVANTAGES
Steam at 175
°
C cleans and sterilises all surfaces perfectly. This machine is especially suitable for removing greasy dirt
because it melts the substance making removal easy with micro fibre cloths or by vacuum cleaning. When used correctly,
this machine can reduce detergent use by more than 80%, and disinfectants by over 90%, thus resolving drainage problems.
This system also reduces labour time by 30%.
This generator is a professional machine with high quality components that comply with all main international safety
standards. The certified boiler is built in high resistance stainless steel. The steam hose connections are equipped with a
double safety block and are manufactured from an original design using specially resistant materials.
MACHINE COMPONENT DESCRIPTION
1
Main switch. This connects the machine on line when turned to ON position. Vice versa, the machine is disconnected
when the switch is in OFF position.
2
Control panel:
A:
Green POWER pilot light
E:
Green HEATING pilot light
B:
Red FAILURE pilot light
F:
Green WATER PUMP pilot light
C:
Green FULL BOILER pilot light
G:
Green SOAP PUMP pilot light
D:
Yellow EMPTY BOILER pilot light
H:
Green STEAM pilot light
I:
SOAP ON button
K:
DRAIN button
3
Multiple socket:
3A=
Steam socket;
3B=
Vacuum tube;
3C=
Presa corrente con bloccaggio di protezione
4
Adjustment knob for steam control. This varies the quantity of steam required by rotating in clockwise or opposite
direction.
5
Pressure gauge to indicate steam pressure in the boiler.