20.
If the water tanks do not fill within 5 minutes the water inlet valve will automatically close.
This feature is a safety feature that prevents the continuous running of water in the case of
a water leak. An error screen indicating a possible leak will be displayed. To clear the
dispenser of this condition, turn the power off and then back on.
21.
Push the Lavit Button again and the tanks will then automatically fill to capacity and shut
off and the Lavit button halo will be blue.
22.
While the water tanks are filling and the compressor is chilling the water, set the current
date and time by pressing the gear shaped Service Icon on the lower left of the HOME
screen.
23.
From the Date/Time Screen, enter the Service Menu by pressing the Service Setup icon.
24.
From the Service Menu select and make the following choices:
Enter MAX TEMP and
DISABLE (when disabled the icon will read “Enable”).
Set the Filter Timer to ENABLE (when enabled the icon will read “Disable”) and reset the
timer if the filter life is to be tracked by the unit. The filter icon on the HOME screen will
change to RED when enabled and six months have passed.
Enable or Disable Sleep Mode.
Select WATER SETUP and display the water calibration screen. Calibrate the three
water streams (mix, still and sparkling) by following the Water Calibration
Procedure found at the end of this Section 2, Page 25.
25.
After completing the water calibration return to the HOME screen by pressing the Return
Arrow in the upper left of the touchscreen to back out of all service screens.
26.
Check for CO
2
leaks, check for water leaks.
27.
The dispenser should now be ready to use after the dispenser reaches temperature. The
first cooling cycle will take approximately 70 minutes.
28.
Enable and set the MAX TEMP if so desired to ensure that every beverage is served chilled.
It is recommended that this feature is Disabled unless a user has asked for colder
beverages.
16
TM170915-B
Summary of Contents for LB115 Series
Page 4: ...4 NOTES...
Page 5: ...Section 1 The Lavit Beverage DispenserOverview Lavit Document TM170915 A 5...
Page 53: ...52 TM170915 B Appendix A Flow Diagram...
Page 54: ...53 TM170915 B Appendix B Electrical Schematic 1...
Page 55: ...54 TM170915 B Appendix C Electrical Schematic 2...
Page 56: ...55 TM170915 B Appendix D Exploded Parts Detail...
Page 57: ...56...
Page 58: ...57 TM170915 B Appendix D Exploded Wetted Parts Detail...
Page 59: ...58 TM170915 B...