44
TM170915-B
bottle. An empty bottle will result in a dry capsule dispense.
3.
A faulty mix stream solenoid will cause a dry powder dispense. To
check if there is a faulty solenoid, locate on the main PCB the blue
plug marked RINSE. Make a beverage. The RINSE solenoid and the
MASTER solenoid should come on together and allow water to into
the capsule. Both the RINSE and the MASTER plugs on the main PCB
have a red LED adjacent to them. If the LEDS light and the solenoid
does not open and allow water into the capsule then change the
RINSE solenoid.
4.
If the silicone dispense nozzle has been dislodged a dry or partial
beverage dispense can occur. Ensure that the nozzle is properly
positioned.