www.la-va.com
11
3. Setup
3.1 Assembling of the stainless
steel skirt
Hold the Sous Vide Stick LX.20 with the heating ele-
ment upwards and open the clamp. Slide the stainless
steel skirt over the heating rods so that the arrow
points to the opened lock symbol.
Make sure that the propeller does not get caught. It
must be positioned in the centre of the hole in the
clear plastic cover.
Rotate the stainless steel skirt until the arrow points
to the closed lock symbol.
For disassembling turn the stainless steel skirt until
the arrow points to the open lock symbol. Carefully
pull the stainless steel skirt from the heating ele-
ments.
Make sure that the propeller does not touch the
stainless steel skirt as it can easily be deformed.
3.2 Setup clamp and pot
Sous Vide Stick LX.20 requires a heat-resistant 5-20
litres container or pot.
Firmly lock the product by clamping it on the side
of your container. Make sure that there is enough wa-
ter in the container above the MIN level on the stain-
less steel skirt.
We recommend to use the pot with lid with the
article number LX0027 matching to Sous Vide Stick
LX.20
.
3.3 Setup Temperature and Timer
Plug it into the outlet. The operating light illuminates
red. The Sous Vide Stick LX.20 is in standby mode.
Press the
icon to enter the setting mode. The
operating light and the
button illuminates blue.
Temperature setting: Press the
or
adjust
button to set the temperature. The temperature can
be set in 0.5°C steps.
Time setting (hh:mm): Press the
icon to set the
time. You can find the timer blinks. First press the
or
adjust button to set hour. Then press
again
to set the minute.
With pressing the icon
you can go back to tem-
perature setting.
Press the icon
to confirm the setting and the
unit will work.
The timer will countdown when it meets the setting
temperature. The operating light illuminates blue.
If you want to change the setting, press and hold the
icon
for 3 seconds, then repeat the setting as
described above.
•
When reaching setting temperature there will
be 2 sounds of beep and operation light flash-
es blue. When it runs out of time there will be
3 sounds of beep and END icon will appear on
the screen. The unit stops automatically and
switches to standby mode. The operation light
illuminates red.
•
During heating up, the control interface will
show the current temperature. After reaching
setting time and start to count down the set
time, the control interface will show the count-
down time. The two digitals will be automatically
interchanged for every 5 seconds.