8
Laundrylux
112999-1
Formula:
(LCdE/AtSt) (tFAS) = Vended Time for “ LCdE”
(25¢/50¢) (30) = 15 minutes
Settings: PL09 (LCdE) ...................... 25
PL11 (tFAS) ........................ 30
PL12 (AtSt) ........................ 50
(Dual Coin)
In the Accumulative Time (AtIn) Mode, when using a dual coin
acceptor, once the “Amount To Start” (“AtSt”) has been inserted,
the addition of a coin(s) yields more time.
The vended time for additional coins is determined by the
Phase 5 coin microprocessor controller (computer) calculation.
There is no calculation required by the owner.
Formula:
(LCdE/AtSt) (tFAS) = Vended Time
Example No. 1: Using a 10¢/25¢ dual coin acceptor with the
desired “Amount to S tart” (“AtSt”) being 25¢ for 15 minutes,
each additional 10¢ would yield the following:
Formula:
(LCdE/AtSt) (tFAS) = Vended Time for “LCdE”
(10¢/25¢) (15 minutes) 6 minutes
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 15
PL12 (AtSt) ........................ 25
Example No. 2: If the dryer is equipped with a 10¢/25¢ dual
coin acceptor and the desired “Amount To Start” (“AtSt”) is
35¢ for 14 minutes, each additional 10¢ inserted would yield
4 minutes and each additional 25¢ would yield 10 minutes.
Formula:
(LCdE/AtSt) (tFAS) = Vended Time for “LCdE”
(10¢/35¢) (14 minutes) 4 minutes
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 14
PL12 (AtSt) ........................ 35
Example No. 3: If the dryer is equipped with a 10¢/25¢ dual
coin acceptor and the desired “Amount To Start” (“AtSt”) is
55¢ for 33 minutes, each additional 10¢ inserted would yield
6 minutes, and each additional 25¢ would yield 15 minutes.
Formula:
(LCdE/AtSt) (tFAS) = Vended Time for “LCdE”
(10¢/55¢) (33 minutes) 6 minutes
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 33
PL12 (AtSt) ........................ 55
NOTE: If the total Vend Time cannot be divided evenly by
the “Amount To Start” (“AtSt”), the “Time For Amount To
Start” will calculate precisely the amount of the time
entitled to the purchaser.
Formula:
(LCdE/AtSt) (tFAS) = Vended Time for “LCdE”
(10¢/35¢) = 2.85 minutes
(2 minutes and 51-seconds)
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 10
PL12 (AtSt) ........................ 35
Accumulative Coin (ACOn)
When this program mode (“ACOn”) is selected, additional time
can only be achieved when the “Amount For Additional Time”
(“AFAt”) PL13 has been inserted.
NOTE: When programming, to use the Accumulative Coin
Mode (“ACOn”), the following parameters/programs need
to be checked and/or changed accordingly:
Settings: PL01 ......................... “ACOn”
(“Accumulative Coin”)
PL13 ........................... “AFAt”
(“Amount For Additional Time”)
(Single Coin Acceptor)
Example No. 1: Using a 25¢ coin acceptor with the desired
“Amount To Start” (“AtSt”) being 50¢ for 24 minutes, the Phase
5 coin microprocessor controller (computer) would yield more
time (24 minutes) only when an additional 50¢ is inserted.
For this application, the “Time For Amount To Start” (“tFAS”)
program (PL11) is determined as follows:
Formula:
(AFAt/AtSt) (tFAS) = Vended Time for “AFAt”
(50¢/50¢) (24 minutes) = 24 minutes
Settings: PL09 (LCdE) ...................... 25
PL11 (tFAS) ........................ 24
PL12 (AtSt) ........................ 50
PL13 (AFAt) ....................... 50
(Dual Coin Acceptor)
With a dual coin acceptor the “T ime For Amount To S tart”
(“tFAS”) is determined as shown below:
Formula:
(AFAt/AtSt) (tFAS) = Vended Time for “AFAt”
Example No. 1: Using a 10¢/25¢ dual coin acceptor the desired
“Amount To Start” (“AtSt”) is 50¢ for 20 minutes and the
“Amount for Additional Time” (“AFAt”) is set for 20¢ each
additional 20¢ would yield 8 minutes.
Formula:
(AFAt/AtSt) (tFAS) = Additional Vended Time
(20/50) (20 minutes) = 8 minutes
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 20
PL12 (AtSt) ........................ 50
PL13 (AFAt) ....................... 20
Example No. 2: If the dryer is equipped with a 10¢/25¢ dual
coin acceptor and the desired “Amount To Start” (“AtSt”) is
35¢ for 14 minutes and the “Amount For Additional Time”
(“AFAt”) is set for 25¢, each additional 25¢ inserted would
yield 10 minutes.
Formula:
(AFAt/AtSt)(tFAS) = Vended Time for “AFAt”
(25¢/35¢) (14 minutes) = 10 minutes
Settings: PL09 (LCdE) ...................... 10
PL10 (rCdE) ....................... 25
PL11 (tFAS) ........................ 14
PL12 (AtSt) ........................ 35
PL13 (AFAt) ....................... 25
Summary of Contents for DAWS0 SERIES