Program Selection ____________________

NOTE: Programs are stored in the Phase 5 coin
microprocessor controller (computer) memory and are
cataloged as PL.

Temperature Display Mode

By closing the PS located on the back side of the Phase 5

coin microprocessor controller (computer), the L.E.D. display

will read the temperature in the dryer in either Fahrenheit (°F)

or Celsius (°C), depending on how the temperature conversion

status is in PL01.   The temperature display mode can be

activated while the dryer is in the operating cycle, or of

f.  While

in the operating cycle, the circuit indicators are visible for

troubleshooting purposes.

NOTE: The dryer cannot be started while the Phase 5 coin
microprocessor controller (computer) PS is closed, unless
the cycle was already in progress.

Right Coin Count (rCC)/Left Coin Count (LCC)

The “HI TEMP” key lets the operator review the coin counters.

If the operator presses the “HI  TEMP” key, the computer

displays “_LCC.”   The operator could then press either the

“PERM PRESS” key to view the “Lef t Coin Count” or the “HI

TEMP” key and the computer would display “_rCC.”   Again,

the operator could press the “PERM PRESS” key to view the

“right coin count.”  While displaying the coin count, if the

operator presses the “HI  TEMP” key the computer then

displays “CxCC” (x = “r” or “L”) to indicate “clearing” the coin

count.  The operator then presses the “PERM PRESS” key to

clear the coin count or the “HI  TEMP” or “LO  TEMP” key to

exit without clearing the coin count.

Automatic Review of Program Location

This selection allows for the  AUTOMATIC REVIEW of what

the program locations are set (programmed) for , thereby

eliminating the need to go into each and every PL manually

for verification.  By closing the PS with no cycle in progress,

the L.E.D. display will read the temperature in the dryer

.  Then,

by pressing the “LO  TEMP” key, the L.E.D. display will read

“PLOC” for 1-second.  Then, the Phase 5 coin microprocessor

controller (computer) will go into the Automatic Review Mode,

the Program Location numbers (i.e., PL01, PL02, etc.) will not

be shown and each parameter (i.e., “°FAr,” “tInE,” “Grd,” etc.)

will be displayed for approximately 1-second each.   The

Automatic Review can be stopped/exited at any time by simply

pressing the “PERM PRESS” key , at which time the L.E.D.

display will read “0000” for 1-second and then return to the

Temperature display mode.

PL01 – Temperature Conversion Status

This program controls whether the temperature related

programs will be operated in Fahrenheit (°F) or Celsius (°C).

The programs affected are:
1. Temperature Display Mode
2. Selection Cycling Temperatures
3. Cool Down Temperatures

Automatic Mode (AUtO) Patent No. 4,827,627

When this parameter (“AUtO”) is selected, the dryer will run

for a preset level of dryness (PL02) or until the programmed

automatic maximum time (PL14) has expired.
At the end of the drying cycle, the dryer will go into the cool

down cycle for the time period programmed (PL04, PL06, or

PL08) or until the temperature has dropped to the programmed

cool down temperature (PL04, PL06, or PL08).

NOTE: Due to humidity, atmospheric pressure, percentage
of extraction, etc., the desired dryness level may vary.  It is
suggested that the owner determine which level of dryness
(90% to 100%) is best suited for his/her application by
experimenting with a few test loads.

When programming, to use the Automatic Mode (“AUtO”)
(Patent No. 4,827,627), the following parameter/programs
need to be checked and/or changed accordingly:

PL01 .......... “AUtO”

“FrEE” or “Coin” (coins required to start)

PL02 .......... “PdrY” (percent dry from 90% to 100%)

PL14 .......... “Adrt” (maximum auto dry time)

PL17 .......... “A” and “b” Factors

Summary of Contents for DAWS0 SERIES

Page 1: ...ass by itself Part No 112999 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS W D R Y E R O P E R AT I N...

Page 2: ...These instructions must be posted in a prominent location near the dryer In the S tate of Massachusett s the following inst allation instructions apply Installations and rep airs must be performed by...

Page 3: ...ny minimum amount COIN COUNT The number of coins inserted including a sep arate display program for optional dual coin acceptors can be viewed through the Phase 5 computer s L E D display BAD COIN LOC...

Page 4: ...dicate failure AUTOMATIC DRY TIME This program selection allows the dryer to run up to a specific time During the AUtO mode or FrEE dry mode this program is only designed to limit the dryer s operatio...

Page 5: ...ing a cycle both the heat and motor will stop However the Phase 5 coin microprocessor controller computer will continue to count downwards in time Continuation of the cycle will resume only after the...

Page 6: ...y for verification By closing the PS with no cycle in progress the L E D display will read the temperature in the dryer Then by pressing the LO TEMP key the L E D display will read PLOC for 1 second T...

Page 7: ...Mode Patent No 4 827 627 NOTE When programming the use of the Coin Mode Coin the following parameter programs need to be checked and or changed accordingly PL01 AUtO automatic drying cycle or tInE tim...

Page 8: ...ser Formula LCdE AtSt tFAS Vended Time for LCdE 10 35 2 85 minutes 2 minutes and 51 seconds Settings PL09 LCdE 10 PL10 rCdE 25 PL11 tFAS 10 PL12 AtSt 35 Accumulative Coin ACOn When this program mode A...

Page 9: ...the end of the drying cycle the Phase 5 microprocessor controller computer will start the cooling cycle for the cool down time programmed or until the temperature has dropped to the programmed cool d...

Page 10: ...have not been preprogrammed by the factory and must be programmed if the Phase 5 microprocessor controller computer programming is changed to be used in the Automatic Mode The A and b Factors must be...

Page 11: ...________________ ____________________________________________________________ The HI TEMP or LO TEMP key provide the following functions Change numeric values HITEMP increases and LO TEMP decreases Fl...

Page 12: ...election button Display Reads To accelerate advance press and hold in HI Temp selection button Display Reads Program Location and will advance until HI Temp selection button is released To revert back...

Page 13: ...advance downward until LO Temp selection button is released To enter a specific program location i e PL01 push the Perm Press selection button Display will read specific program location called up To...

Page 14: ...Temperature Display Mode and or Amount To Start Dryer Temperature Display Temperature Selection Time Cycle In Progress Dryer Temperature Display FILL 25 Close Program Switch 75F HI 2 0 13 5 F 135F Clo...

Page 15: ...Temp Display will read 0000 for 1 second and then dryer temperature display To cancel or delete left coin count press HI Temp key Display will read CLCC cancel left coin count Press Perm Press key an...

Page 16: ...ns To retain or save existing coin count press Perm Press Display will read 0000 for 1 second and then dryer temperature display To cancel or delete right coin count press HI Temp key Display will rea...

Page 17: ...program mode close program switch Dryer Temperature Display Press Perm Press key Display will read PL01 program location 01 Press Perm Press key Display will read temperature conversion status either...

Page 18: ...ey otherwise press HI or LO key and then Perm Press key Display will read vend status either Coin coins required to start or FrEE no coins required If no change press Perm Press key otherwise press HI...

Page 19: ...r flash FLS If no change press Perm Press key otherwise press HI or LO key and then Perm Press key If no flash is selected display will read fixed display status I E AtSt amount to start dryer or Free...

Page 20: ...ram mode open program switch or or or or Display will read coin time accumulation status I E AtIn accumulative time or ACOn accumulative coin If no change press Perm Press key otherwise press HI or LO...

Page 21: ...Temp Perm Press To exit program mode open program switch LO Temp Refer to Programming Instructions for instructions on entering program locations Proceed to next location to be changed Wait 3 Seconds...

Page 22: ...and then Perm Press key Temperature Increase Temperature Decrease Summary HI Temp is programmable from a minimum of 100 F to a maximum of 190 F in ten degree increment s or from a minimum of 38 C to...

Page 23: ...re is programmable from a minimum of 70 F to a maximum of 190 F in ten degree increments or from a minimum of 21 C to a maximum of 88 C in five degree increments Cool down is programmable from 0 to 9...

Page 24: ...s Perm Press key Display will read LO F LO Temp status for 3 seconds and then the actual temperature programmed If no changes press Perm Press key otherwise press HI or LO key and then Perm Press key...

Page 25: ...tion to be viewed changed Press Perm Press key Display will read LOCd LO Temp cool down status for 3 seconds and then the actual temperature and time programmed If no changes press Perm Press key twic...

Page 26: ...LO key and then Perm Press key Temperature Decrease Temperature Increase Summary Perm Press Temp is programmable from a minimum of 100 F to a maximum of 190 F in ten degree increments or from a minimu...

Page 27: ...emperature is programmable from a minimum of 70 F to a maximum of 190 F in ten degree increments or from a minimum of 21 C to a maximum of 88 C in five degree increments Cool down is programmable from...

Page 28: ...ination is programmable from 1 to 9999 IMPORTANT When the dryer is equipped with a dual coin acceptor the value set here is the lower value denomination which is not necessarily the left coin portion...

Page 29: ...ogrammable from 1 to 9999 IMPORTANT When the dryer is equipped with a dual coin acceptor the value set here is the higher value denomination which is not necessarily the right coin portion of the acce...

Page 30: ...rm Press key otherwise press the HI TEMP key or the LO TEMP key and then press the Perm Press key Summary The time for amount to start is programmable from 1 to 99 minutes PL11 tFAS Perm Press 4 HI Te...

Page 31: ...s key otherwise press HI or LO key and then Perm Press key Summary The amount to start is programmable from 1 to 9999 PL12 AtSt Perm Press 25 HI Temp Perm Press LO Temp Refer to Programming Instructio...

Page 32: ...hen Perm Press key Program Location 13 PL13 Coin Accumulation Minimum Amount for More Time Summary The amount to start is programmable from 1 to 9999 Amount Decrease Amount Increase PL13 AFAt Perm Pre...

Page 33: ...m Press key otherwise press HI or LO key and then Perm Press key Summary The maximum auto dryness time is programmable from 1 to 99 minutes PL14 Adrt Perm Press 25 HI Temp Perm Press LO Temp Refer to...

Page 34: ...conds Time Increase Time Decrease Time Increase Time Decrease PL15 GdLY Perm Press 2 HI Temp Perm Press LO Temp Refer to Programming Instructions for instructions on entering program locations Wait 3...

Page 35: ...rogram Location 16 PL16 and Program Location 17 PL17 Maximum Active Anti Wrinkle Time Location to be viewed changed Press Perm Press key Display will read AGt maximum guard time for 3 seconds and then...

Page 36: ...ple A 5 Factors b is adjustable from 1 to 99 example B 75 Phase 5 Coin System Diagnostics ___ All major circuits including door microprocessor temperature sensor heat and motor circuits are monitored...

Page 37: ...s in the Phase 5 microprocessor controller computer itself If the motor is not operating and the MTR output indicator is on then the problem is elsewhere external of the microprocessor controller comp...

Page 38: ...Part No 112999 1 xx xx 12...