6
Laundrylux
112999-1
Program Selection ____________________
NOTE: Programs are stored in the Phase 5 coin
microprocessor controller (computer) memory and are
cataloged as PL.
Temperature Display Mode
By closing the PS located on the back side of the Phase 5
coin microprocessor controller (computer), the L.E.D. display
will read the temperature in the dryer in either Fahrenheit (°F)
or Celsius (°C), depending on how the temperature conversion
status is in PL01. The temperature display mode can be
activated while the dryer is in the operating cycle, or of
f. While
in the operating cycle, the circuit indicators are visible for
troubleshooting purposes.
NOTE: The dryer cannot be started while the Phase 5 coin
microprocessor controller (computer) PS is closed, unless
the cycle was already in progress.
Right Coin Count (rCC)/Left Coin Count (LCC)
The “HI TEMP” key lets the operator review the coin counters.
If the operator presses the “HI TEMP” key, the computer
displays “_LCC.” The operator could then press either the
“PERM PRESS” key to view the “Lef t Coin Count” or the “HI
TEMP” key and the computer would display “_rCC.” Again,
the operator could press the “PERM PRESS” key to view the
“right coin count.” While displaying the coin count, if the
operator presses the “HI TEMP” key the computer then
displays “CxCC” (x = “r” or “L”) to indicate “clearing” the coin
count. The operator then presses the “PERM PRESS” key to
clear the coin count or the “HI TEMP” or “LO TEMP” key to
exit without clearing the coin count.
Automatic Review of Program Location
This selection allows for the AUTOMATIC REVIEW of what
the program locations are set (programmed) for , thereby
eliminating the need to go into each and every PL manually
for verification. By closing the PS with no cycle in progress,
the L.E.D. display will read the temperature in the dryer
. Then,
by pressing the “LO TEMP” key, the L.E.D. display will read
“PLOC” for 1-second. Then, the Phase 5 coin microprocessor
controller (computer) will go into the Automatic Review Mode,
the Program Location numbers (i.e., PL01, PL02, etc.) will not
be shown and each parameter (i.e., “°FAr,” “tInE,” “Grd,” etc.)
will be displayed for approximately 1-second each. The
Automatic Review can be stopped/exited at any time by simply
pressing the “PERM PRESS” key , at which time the L.E.D.
display will read “0000” for 1-second and then return to the
Temperature display mode.
PL01 – Temperature Conversion Status
This program controls whether the temperature related
programs will be operated in Fahrenheit (°F) or Celsius (°C).
The programs affected are:
1. Temperature Display Mode
2. Selection Cycling Temperatures
3. Cool Down Temperatures
Automatic Mode (AUtO) Patent No. 4,827,627
When this parameter (“AUtO”) is selected, the dryer will run
for a preset level of dryness (PL02) or until the programmed
automatic maximum time (PL14) has expired.
At the end of the drying cycle, the dryer will go into the cool
down cycle for the time period programmed (PL04, PL06, or
PL08) or until the temperature has dropped to the programmed
cool down temperature (PL04, PL06, or PL08).
NOTE: Due to humidity, atmospheric pressure, percentage
of extraction, etc., the desired dryness level may vary. It is
suggested that the owner determine which level of dryness
(90% to 100%) is best suited for his/her application by
experimenting with a few test loads.
When programming, to use the Automatic Mode (“AUtO”)
(Patent No. 4,827,627), the following parameter/programs
need to be checked and/or changed accordingly:
PL01 .......... “AUtO”
“FrEE” or “Coin” (coins required to start)
PL02 .......... “PdrY” (percent dry from 90% to 100%)
PL14 .......... “Adrt” (maximum auto dry time)
PL17 .......... “A” and “b” Factors
Summary of Contents for DAWS0 SERIES