28
Program Location 09 (PL09)
Left Coin Denomination
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “LCdE,” left coin
denomination for 3-seconds and the
left coin acceptor denomination
programmed (I.E. 25¢). If no
change, press “Perm Press” key,
otherwise press “HI” or “LO”
key and then “Perm Press” key.
Amount Decrease
Amount Increase
Summary: The left coin denomination is programmable from 1 to 9999.
IMPORTANT: When the dryer is equipped with a dual coin acceptor, the value set here is the lower value denomination,
which is not necessarily the left coin portion of the acceptor.
NOTE: For single coin models this parameter must be set for the value of the acceptor. I.E. 25¢ acceptor = 25.
PL09
LCdE
Perm Press
10
HI Temp
Perm Press
LO Temp
Refer to Programming
Instructions for instructions on
entering program locations.
(Wait 3-Seconds)
("Hold In" to Accelerate)
("Hold In" to Accelerate)
PL10
Proceed to next location
to be changed
To exit program mode,
open program switch
Summary of Contents for DAWS0 SERIES
Page 38: ...Part No 112999 1 xx xx 12...