LAUNCH
BST-460 Battery System Tester User Manual
17
Operate accordingly to increase the engine rotating speed to above
3000 revolutions, and keep it for 5 seconds.
The tester starts the charging volt test after an increased revolution is
detected. See below picture:
After the test finished, the tester displays the valid charging volts,
ripple test result and charging test result. See below picture:
NOTE:
If no increased rev is detected, it shall be the fault of generator
regulator or connection with battery failed. The tester will try 3 times
to further detect, if still failed, it will skip the increase rev detect and
the test result displays "No Output". See below picture:
Check the connection between generator and battery, then re test.
Charging Test Result:
1) Charging Volt: Normal
Charging system shows the generator
’s output is normal, no