![background image](http://html1.mh-extra.com/html/launch/bst-460/bst-460_user-manual_3864213006.webp)
LAUNCH
BST-460 Battery System Tester User Manual
2
Cranking test
is used to test and analyze the starting motor. Testing the actual
required cranking current and cranking voltage of the starting motor is helpful
to determine whether the starting motor works properly or not. If the starting
motor runs improperly, find the possible reasons: lubricating system
malfunction may cause an increased starting loaded torque; or rotor friction of
the starting motor generates an increasing friction of the starting motor itself.
Charging test
is to check and analyze the charging system, including
generator, rectifier, rectifier diode, etc., thus to find out whether the output
voltage of the generator is normal, the rectifier diode works properly and the
charging current is normal. In case one of the above mentioned parts is
abnormal, it will lead to over charge or incomplete charge of the battery, thus
cause quick damage to the battery and greatly shorten the life of other loaded
appliance.
Additional functions
include: Set language, Set voltmeter and screen
brightness adjustment.
1.3 Technical Parameters
1. Cold Cranking Amps Measurement Range:
Measurement Standard
Measurement Range
CCA
100-2000
BCI
100-2000
CA
100-2000
MCA
100-2000
JIS
26A17--245H52
DIN
100-1400
IEC
100-1400
EN
100-2000
SAE
100-2000
GB
100-1400