![Lauda ECO Silver E 4 S Operation Manual Download Page 88](http://html1.mh-extra.com/html/lauda/eco-silver-e-4-s/eco-silver-e-4-s_operation-manual_4087659088.webp)
88 / 124
ECO Silver
33
RTC wrong data
Internal clock defective
33
valve sm0 break
Cable of injection valve 0 defective
41
wrong net voltage
Incorrect mains voltage setting
34
valve sm1 break
Cable of injection valve 1 defective
42
no eco type
Device type not configured
35
valve sm2 break
Cable of injection valve 2 defective
43
no eco voltage
Mains voltage not configured
36
valve sm3 break
Cable of injection valve 3 defective
44
chiller missing
Chiller not running
37
output sm0
Triggering of injection valve 0 defective
45
Diff.voltages
Different mains voltage configured (head
and cooling underpart)
38
output sm1
Triggering of injection valve 1 defective
46
# of heaters
Setting the heater configuration
39
output sm2
Triggering of injection valve 2 defective
40
output sm3
Triggering of injection valve 3 defective
41
sm0 min too small
Start value of injection valve too small
42
no eco type
Device type not configured
43
no eco voltage
Mains voltage not configured
44
chiller missing
Chiller not running
Code 1XX Safety system
Meaning
Code 2XX Command
Meaning
1
CAN receive overf
Overflow during CAN reception
1
CAN receive overf
Overflow during CAN reception
2
Watchdog Reset
Watchdog reset
2
Watchdog Reset
Watchdog reset
5
Heat 1 failed
Heater 1 defective
3
Clock Error
Battery fault
6
Heat 2 failed
Heater 2 defective
9
Unknown Modul
Unknown module connected
7
Invalid Parameter
Inadmissible parameter in memory
10
SW control too old
Software version of control panel too old
8
CAN system
Problem during internal data interchange
11
SW safety too old
Software version of protection too old
9
Unknown Modul
Unknown module connected
12
SW command too old Software version of command remote
control unit too old
10
SW control too old
Software version of control panel too old
13
SW cool too old
Software version of cooling module too
old
11
SW safety too old
Software version of protection too old
14
SW analog too old
Software version of analog too old
12
SW command too old Software version of command remote
control unit too old
15
SW serial too old
Software version of RS 232 too old
13
SW cool too old
Software version of cooling module too
old
16
SW contact old
Software version of contact module too
old
14
SW analog too old
Software version of analog too old
17
SW Valve 0 old
Software version of solenoid valve 0 too
old
15
SW serial too old
Software version of RS 232 too old
18
SW Valve 1 old
Software version of solenoid valve 1 too
old
16
SW contact old
Software version of contact module too
old
19
SW Valve 2 old
Software version of solenoid valve 2 too
old
17
SW Valve 0 old
Software version of solenoid valve 0 too
old
20
SW Valve 3 old
Software version of solenoid valve 3 too
old
18
SW Valve 1 old
Software version of solenoid valve 1 too
old
21
SW Valve 4 old
Software version of solenoid valve 4 too
old
19
SW Valve 2 old
Software version of solenoid valve 2 too
old
26
SW HTC old
Software version of high temperature
cooler too old
20
SW Valve 3 old
Software version of solenoid valve 3 too
old
21
SW Valve 4 old
Software version of solenoid valve 4 too
old
26
SW HTC old
Software version of high temperature
cooler too old
27
SW Ext Pt100 old
Software version of external Pt100 too
old
Summary of Contents for ECO Silver E 4 S
Page 1: ...ECO Silver Operation manual...
Page 2: ......
Page 4: ......
Page 78: ...78 124 ECO Silver 10 2019 i...
Page 79: ...10 2019 i ECO Silver 79 124...
Page 80: ...80 124 ECO Silver 10 2019 i Appendix with settings...
Page 111: ...10 2019 i ECO Silver 111 124 5 Click on Continue installation 6 Click on the key Finish...
Page 113: ...10 2019 i ECO Silver 113 124...
Page 120: ...120 124 ECO Silver 10 2019 i Blank page...
Page 121: ...10 2019 i ECO Silver 121 124 Blank page...
Page 122: ...122 124 ECO Silver 10 2019 i...
Page 125: ......
Page 126: ......
Page 127: ......