BL55-RU
(E)
3-7
Protrusion
Scale unit side
Scale unit side
Mounting brackets to the slider top
Fig. 3-8
Align the slider top and mounting bracket, and adjust the mounting bracket so that the distance from the
alignment surface is 19
±
0.1 mm. Make the parallelism and flatness of the alignment surface as shown in
Table 3-2.
Washer/Nut: .......................... Plain washer with nominal size 4: 2 washers/Hex. nuts with nominal size 4: 2
nuts
Screw/Tightening torque: ..... M4
×
25: 2 pcs. / 2.7 N
·
m
3-4-4. Removing the Slider Holder
Remove the slider holder after attaching the slider.
The slider holder can be removed from the slider with a one-touch operation.
There is a protrusion on the scale unit side of the slider. The slider holder fits into this protrusion. Use the
following procedure to remove the slide holder.
1
Pull out the slider holder in the lengthwise direction so that the protrusion on the scale unit side is passed
over, and then separate the slider and slider holder.
Fig. 3-9
19 (0.748")
±
0.1 (0.004")
M4 nut
Slider unit
Mounting bracket
Scale unit
Unit: mm (inch)