background image

LaserBit PicoPlus Series 1.0                                     page     

15 

 

6.3 Distance measurement 

 
Because the units were designed, and calibrated for certain distance operations the 
higher distance will decrease the availability. Laserbit pre-calibrates and pre-tests 
every unit shipped to the customer. To ensure that the unit you are about to buy fits 

to the needs, the first step is to 
measure the distance. The best 
way to measure it is by GPS 
(Global Positioning 
System), these units 
are accurate enough to 
determine the distance 
between two points. 
For more details please 
refer to the GPS 

manufacturer 

handbook. Also there are several 
other ways to measure the 
distance. If you know the exact 

address you can use mapping software like MapPoint or Auto route.  
 

6.4 Direct sunshine 

 
To prevent the sun shining directly 
into the receiver optics, first one 
has to determine the orientation of 
the link. Try to avoid East-West 
orientation wherever it is possible. 
Examine both sides of the link at 
sunset and sunrise and find a 
position where the sun cannot get 
behind any of the heads. Be aware 
that the path of the sun is changing 
throughout the year. 

7 Eye 

safety 

 
There are no two installation spots of the same kind, the buildings or structures, the 
available space and the accessibility of the place will be different in each case. 
Nevertheless, as a general rule it is very important to select the installation site so 
that nobody can look directly into the transmitter. For this reason place the head 
either so high (on the side wall of the building) or so close to the edge of the building 
(on a parapet on the rooftop) that no person can approach it accidentally and can get 
into the beam path. Set up barriers if necessary and put warning signs at prominent 
places. 
The laser heads are provided with all labels and hazard warnings required by the 
laser standard. There are warning labels on both the left and right side of the 
protective cover next to the optical window and there is a warning and an informative 
label on the rear side of the laser head. 

 

Summary of Contents for PICO Plus Series

Page 1: ...PICO Plus Users Manual 1 0...

Page 2: ...on ____________________________________________ 13 6 2 Preferred installation sites __________________________________________ 13 6 3 Distance measurement _____________________________________________...

Page 3: ...FSO systems use a laser diode as a light source and a receptor diode photo diode to receive the signals coming from the laser diode from the transmitter side But the basic elements are still the same...

Page 4: ...ction across rivers and other natural or artificial obstacles where cable is not available The transmission technique used in the Laserbit FSO devices provides transparent and wire speed data transfer...

Page 5: ...l is amplified encoded and then drives the laser diode The transmitter optics assures the proper beam shape and controls the beam divergence The receive optics perceives and directs the transmitter si...

Page 6: ...se are Areas with natural or artificial obstacles Where cable is actually not an alternative like across rivers or railways or in rugged terrain Urban areas Where only leased lines are available with...

Page 7: ...ith trainings meetings and other programs and a fine support community The purpose is to manufacture cost effective and best quality products which are simultaneously suitable for telecommunication st...

Page 8: ...walls of buildings where a clear optical path exists between the two sites Next to the head the Outdoor Interconnection Unit provides fast and easy interconnection between the laser head and the cable...

Page 9: ...The Pico Plus PoE systems should be considered as repeaters in the network So the installation distance between the head and the network device is 100m The distance on a back to back site is maximum 5...

Page 10: ...part of the system you will receive E1 multiplexers These multiplexers provide fast and easy connection to the laser device The TC link speed is 2 048Mbps E1 Interface systems layout The PicoPlus E1 r...

Page 11: ...aserBit PicoPlus Series 1 0 page 11 4 Product matrixes 4 1 Interface matrix In the spreadsheet below you can see the interface availability E1 E100TP PicoPlus 4 2 Power supply configuration E1 PicoPlu...

Page 12: ...he Power supply unit and the bracket to the wall below you can see what is provided in the Pico Plus package ODIUs and ODIU accessories only in case of E1 systems 2ps of LB PICO Plus heads 2ps of LB O...

Page 13: ...cases this effect can be avoided by careful selection of the mounting spot In order to comply with the requirements of the successful installation including the discussed four key factors and other c...

Page 14: ...constructs Metal masts or Frames Hidden heat isolations like Styrofoam In cases where installations are listed under AVOID cannot be avoided than special mounting accessories to be designed and speci...

Page 15: ...t is possible Examine both sides of the link at sunset and sunrise and find a position where the sun cannot get behind any of the heads Be aware that the path of the sun is changing throughout the yea...

Page 16: ...ss II EN 60950 1 2001 electrical safety EN 55022 1998 Corr 2001 A1 2000 and EN 55024 1998 Dismounting the cover can cause fatal injury Manufactured by LaserBit Communications Corp 1037 Budapest Kunigu...

Page 17: ...ll with a permanent marker Use your 10mm wall drill to drill all of the holes into the wall Clean the holes Place the wall plugs into the holes please note that some times you need to use hammer to pu...

Page 18: ...l strength LED s Make sure that the Saturation indicator is OFF Adjust your attenuators if necessary to avoid saturation of the receivers Please note that at this short distance specially the longer d...

Page 19: ...he bolts into the holes which is easily accessible for the installation and the two cuts Place up the washers and spring washers Fix the bolts with the nuts After you put up the washers and the nuts d...

Page 20: ...l direction but be careful that the heads do not move out from its position Meanings of the LEDs Power The head is powered up FO Link Fibre optical link between the two heads TP Link Copper link betwe...

Page 21: ...ht hand side and tighten it with the spanner and reach the maximum again We strongly suggest you to repeat the steps 2 3 times to make sure that the bolts are tight 3 In the meantime the remote end sh...

Page 22: ...able This provides the power and the data for the LaserBit Pico Plus laser head The unit has connection for the management on the bottom of the Laser unit Please see the connection below This is the s...

Page 23: ...range 8 5V Whi e 3 Green t GND 4 Blue RS485 5 Blue White RS485 6 Green 8 5VDC White 7 Brown 8 5VDC 8 Brown 30VDC 1 Orange hi RX RX W te 2 Orange Whi e 3 Green t 4 Blue TX 5 Blue White TX 6 Green White...

Page 24: ...er two r the head On the secondary side the fuse ratings are T4A 250V F The outdoor interconnection unit ODIU provides the power supply and data connection The ODIU made from poly propylene enforced w...

Page 25: ...Pull on the metal plate to the legs of the screws Fix the metal plate with four M5 nuts using the four washers and four spring washers like in the figure Then you can fix the whole construction to a w...

Page 26: ...e head to the ODIU and the ODIU to the power supply Ensure that the cables are connected as it seen below For the power connection recommended to use three wired 0 75mm cables The order of the connect...

Page 27: ...signals can be found on the blue and brown wires of the head power cable You have to connect these two wires into two pins of the four of the two green connectors These pins are connected to the pins...

Page 28: ...ding loss of data lost profits lost savings lost business or other incidental or consequential or indirect damages arising out of the installation use maintenance performance failure or interruption o...

Page 29: ...t The foregoing warranties and remedies are exclusive and are in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise including warranties of...

Page 30: ...10 Appendix A a Product registration form Please take your time to fill out Laserbit product registration form to ensure your warranty period begins otherwise Laserbit consider warranty beginning fro...

Page 31: ...LaserBit PicoPlus Series 1 0 page 31 b Failure report form In case of failures please report it to us and fill out the failure report form forward to your distributor...

Page 32: ...LaserBit PicoPlus Series 1 0 page 32 10 1 PICO PLUS Data Sheet...

Reviews: