Laser Technology, Inc. TruPulse 200L User's Manual 1
st
Edition
Page 20
Section 5 - Target Modes
The TruPulse 200L has five Target Modes which allow you to
select or eliminate targets and to take the most accurate
measurements possible in various field conditions
.
1.
From the Measurement Mode, press
for 4 seconds.
The active Target Mode appears in the Main Display.
2.
Press
or
to display the previous or next Target
Mode.
3.
Press
to select the displayed Target Mode and return to
the Measurement Mode.
o
Std = Standard: Single shot mode.
o
Con = Continuous: Press-and-hold
. Once the
target is acquired, the TruPulse 200L can continuously
acquire additional targets for a maximum of 5 seconds.
The most recently acquired target appears in the Main
Display.
o
CLO = Closest: Press-and-hold
. Once the initial
target is acquired, the TruPulse 200L can acquire
additional targets. The
indicator denotes that
additional targets have been acquired. The closest
acquired target always appears in the Main Display.
o
FAr = Farthest: Press-and-hold
. Once the initial
target is acquired, the TruPulse 200L can acquire
additional targets. The
indicator denotes that
additional targets have been acquired. The farthest
acquired target always appears in the Main Display.
o
Flt = Filter: In this mode the laser’s sensitivity is
reduced to only detect pulses returned from a reflector.
The optional foliage filter must be used in conjunction
with this mode. In this mode, measurements always
include ‘F’ as the left most character in the Main
Display. Typical maximum distance is 350 feet to a
3-inch reflector.
Figure #15