Laser Technology TruPulse 200L User Manual Download Page 23

Section 6 - Target Modes 

Page 19 

During the Vertical Missing Line Routine: 

 

Press 

 to re-shoot Shot 1. 

 

Press 

 to exit the Missing Line Routine. 

 

1.

 

Select your first target and look through the 
eyepiece, using the crosshair to aim to your target. 
The 

 indicator displays steady and the 

 

indicator flashes; prompting you to measure the 
Horizontal Distance to the first target. 

2.

 

Press-and-hold 

. The 

indicator is displayed 

while the laser is active. The laser remains active 
for a maximum of  5 seconds while acquiring data 
about the target. The measured horizontal distance 
appears in the Main Display. 

3.

 

Once the 

 button is released, "SHot2" appears 

steady and the 

 indicator flashes (with 

 

steady); prompting you to measure the Horizontal 
Distance to the second target. Looking through the 
eyepiece and using the crosshair to aim to the 
second target. 

4.

 

Press-and-hold 

. The 

 indicator is displayed 

while the laser is active. The laser remains active 
for a maximum of  5 seconds while acquiring data 
about the target. The measured horizontal distance 
to the second target appears in the Main Display. 

5.

 

Once you release 

 and 

 are steady 

and the calculated horizontal distance of the  
missing  line is displayed. The measurement  
displays steady until you press any button or the  
unit powers off. 

At this time, you can: 

 

Press 

 or 

 to scroll and see the other missing line 

measurements results (

,

 

and 

). 

 

Reshoot Shot 2 by pressing 

 or 

 until Shot 2 and ML 

appear steady  
in the display as well as HD flashing, prompting you to measure 
the horizontal  
distance to the second target (or new target). Go to #4 above.  

 

Press 

 to exit the missing line results and return to Shot 1. 

 

Figure #14 

Summary of Contents for TruPulse 200L

Page 1: ...Laser Technology Inc TruPulse 200L User s Manual LTI 2013 PM TruPulse 200L 130 0001 ...

Page 2: ...nts This product is covered by pending patent applications and or the following issued U S Patents 6 445 444 5 612 779 6 057 910 6 226 077 5 652 651 7 920 080 7 619 548 Trademarks Criterion Impulse and TruPulse are trademarks of Laser Technology Inc LTI Contact Information Laser Technology Inc 6912 South Quentin St Centennial CO 80112 3921 USA Phone 1 303 649 1000 1 800 790 7364 USA and Canada Fax...

Page 3: ...Laser Technology Inc TruPulse 200L User s Manual Languages 1 English 2 Español 3 Français 4 Deutsch 5 日本語 6 汉语被简化 ...

Page 4: ......

Page 5: ...stallation 7 Low Battery Warning 7 Buttons 8 Powering OFF the TruPulse 200L 8 Display Indicators 9 Display Indicator Test 11 Error Codes 11 Firmware Revision Number 12 Neck Strap 13 Units of Measure 14 Section 4 Measurement Modes 15 Distance Measurements 15 Notes about Measurements 16 Inclination Measurements 16 Percent Slope 16 Height Routine 17 Vertical 2D Missing Line Routine 18 Section 5 Targe...

Page 6: ... aperture while firing the laser The use of optical instruments with this product may increase eye hazard Never attempt to view the sun through the scope Looking at sun through the scope may permanently damage your eyes Never point the unit directly at the sun Exposing the lens system to direct sunlight even for a brief period may permanently damage the internal components Avoid direct sun exposur...

Page 7: ...clination The Target Mode allows you to select or eliminate targets which helps you take the most accurate measurement possible in a variety of field conditions Flexible 2 or 3 point height routines and 2 dimensional Missing Line routine with auto sequencing Operating Modes Measurement Modes Slope Distance Vertical Distance Horizontal Distance Inclination 3 Point Height Routine Missing Line Target...

Page 8: ...ge Sensor The laser range sensor emits invisible eye safe infrared energy pulses The TruPulse 200L determines distance by measuring the time it takes for each pulse to travel from the rangefinder to the target and back The indicator is displayed whenever the laser is being transmitted The laser may be active for a maximum of 5 seconds Once the target is acquired or the laser has timed out you can ...

Page 9: ...lly the inclination is measured when you press However in 1 the Continuous Target Mode and 2 in the Height Measurement Mode the inclination reading appears in the Main Display and the display updates as your aiming point changes as long as you press In these two situations the measured inclination is based upon the aiming point when you release Digital Processor The TruPulse 200L includes LTI s pr...

Page 10: ...d press or until the indicator is displayed 5 Press and hold The indicator is displayed while the laser is active Figure 3B The laser will remain active for a maximum of 5 seconds while acquiring data about the target o If the target is not acquired release and repeat this step 6 Release once the distance is displayed Figure 3C The measurement will be displayed steady until you press a button or t...

Page 11: ...ed on the top the cover with the grooved edge of the battery compartment and press the cover until the tab locks into position Low Battery Warning The TruPulse 200L monitors the incoming battery voltage Figure 5 shows the location of the battery status indicator When the voltage drops below 2 6V the BATT status indicator flashes every 5 seconds alternating with the normally displayed information o...

Page 12: ...ption and returns to the Measurement Mode UP Measurement Modes Press to scroll to the previous Measurement Mode Press and hold 4 seconds to access the Target Mode Height Routine Clears the last measurement and re displays the previous prompt Target Modes System Setup Mode Press to scroll to the previous option DOWN Measurement Modes Press to scroll to the next Measurement Mode Press and hold 4 sec...

Page 13: ...lination measurement units Degrees Feet Distance measurement units Selection available in the System Setup Mode Meters Yards Battery Status Flashing battery voltage is low Steady battery voltage is too low for system operation Not Visible battery voltage is within acceptable range Crosshair Serves as the aiming point reference both horizontally and vertically Laser Status Visible laser is firing N...

Page 14: ...ent Routine Three step height routine The final calculation represents the vertical distance between the points on the target represented by ANG1 and ANG2 Closest Target Mode The unit logs multiple targets while is held down The circle denotes that additional targets have been acquired Of the targets acquired the distance to the closest target displays Farthest Target Mode The unit logs multiple t...

Page 15: ...urement the TruPulse 200L monitors both system hardware and measurements When the instrument detects an error condition it displays and error code instead of a measurement Error codes appear in the main display and are in the form of Exx where xx is an error code number Figure 7 shows an example error code E36 If an error code persists 1 Release and press again to try to retake the measurement 2 R...

Page 16: ... Start with the TruPulse 200L powered OFF press and hold o Do not release until done If you release the button too early power OFF the TruPulse 200L and repeat step 1 2 Looking through the eyepiece o Press to display the main firmware revision number The display should look similar to the example below 1 02 in Figure 8 o Press to display the instrument serial number The display should look similar...

Page 17: ...rap To attach the neck strap 1 Disconnect the anchor end of the strap using the buckle 2 Feed loop around metal bar 3 Thread the Neckstrap through the loop 4 Gently tighten to secure 5 Reconnect anchor end of the strap using the buckle Figure 9 ...

Page 18: ...stem Setup Mode UnitS will appear in the Main Display 2 Press to select the UnitS option 3 Press or to display the previous or next distance unit option 4 Press to select the displayed distance unit and display the inclination unit option 5 Press or to display the previous or next inclination unit option 6 Press to select the displayed inclination unit and return to the Measurement Mode Each time ...

Page 19: ...e 200L can take Distance Measurements The basic steps for taking any distance measurement 1 Look through the eyepiece and use the crosshair to aim to the target 2 Press and hold The indicator is displayed while the laser is active The laser will remain active for a maximum of 5 seconds while acquiring data about the target o If the target is not acquired in the 5 second period release and repeat t...

Page 20: ... target Each time the TruPulse 200L is powered ON it will return to the same measurement mode that was last used Inclination Measurements The laser is not active in the Inclination Measurement Mode Generally the inclination is measured when you press However in 1 the Continuous Target Mode and 2 in the Height Measurement Mode the inclination reading appears in the Main Display and the display upda...

Page 21: ...ator is displayed while the laser is active The laser will remain active for a maximum of 5 seconds while acquiring data about the target The measured horizontal distance appears briefly in the Main Display and then Ang_1 appears and the indicator flashes prompting you to measure the inclination to base or top of the target 3 Press and hold and aim to the base or top of the target The measured inc...

Page 22: ...he height result is displayed just press to start the routine and repeat the steps Vertical 2D Missing Line Routine The Vertical 2D Missing Line Routine Displays Horizontal Distance Vertical Distance Slope Distance and Inclination between two remote points The Vertical 2D Missing Line Routine calculates distances and angles to describe the relationship between two points in two dimensional space c...

Page 23: ...al Distance to the second target Looking through the eyepiece and using the crosshair to aim to the second target 4 Press and hold The indicator is displayed while the laser is active The laser remains active for a maximum of 5 seconds while acquiring data about the target The measured horizontal distance to the second target appears in the Main Display 5 Once you release and are steady and the ca...

Page 24: ...st recently acquired target appears in the Main Display o CLO Closest Press and hold Once the initial target is acquired the TruPulse 200L can acquire additional targets The indicator denotes that additional targets have been acquired The closest acquired target always appears in the Main Display o FAr Farthest Press and hold Once the initial target is acquired the TruPulse 200L can acquire additi...

Page 25: ...until you repeat the above steps and select a different Target Mode Each time the TruPulse 200L is powered ON it will return to the same Target Mode that was last used In Closest and Farthest Modes the minimum separation distance between targets is approximately 20 meters ...

Page 26: ...rument and should be handled with care It will withstand a reasonable drop shock If the unit suffers from a severe drop shock you may need to send the unit to LTI for service repair Transporting When transporting the TruPulse 200L the unit should be secured in the provided carrying case The provided neck strap can be used when carrying the TruPulse 200L in the field Cleaning Clean the TruPulse 200...

Page 27: ...1 m to 1 750 m to reflective target 3 to 3 280 ft 1 m to 1 000 m typical to non reflective Range Accuracy 3 ft 1 m to any target at any range Range Resolution 1 ft yd m Range Units Feet Yards and Meters Inclination Limits 90 degrees Inclination Accuracy 0 5 degrees Inclination Resolution 0 5 degree 1 Inclination Units Degrees Slope Power 3 0 volts DC nominal 1 CR123A battery Alkaline NiCd NiMH Lit...

Page 28: ...rs are active the Main Display looks like Numbers 0 9 Alpha Characters a g r d i s e l t f n u Due to the limited number of characters available many messages have to be abbreviated The table below lists the messages that appear in the Main Display Message Explanation Page Angle 1 Height Routine 17 Angle 2 Height Routine 17 Farthest target mode 20 Filter target mode 20 Standard target mode 20 Unit...