Upload Serial Data Commands
START_MEASUREMENT:
GO = Single shot
(will output “E01” if no target found after 15 seconds)
STOP_MEASUREMENT:
ST
SET_DISTANCE_UNITS:
MU
Meters:
0
Yards: 1
Feet:
2
Note: Only International lasers include meters.
SET_MEASUREMENT_MODE:
MM
Horizontal Distance:
0
Vertical Distance:
1
Slope
Distance:
2
Inclination:
3
Height:
4
Missing
Line
6
SET_TARGET_MODE:
TM
Normal:
0
Continuous:
1
Closest:
2
Farthest:
3
Filter: 4
GET_BATTERY_VOLTAGE:
BV
(millivolts)
Example Reply:
3125 = 3.125 volts
SET_POWER
_OFF
PO
Get
ID $ID
response:
$ID,TP200
MAIN,4.21,10-20-2015,103529
$PLTIT,RQ,ID
response:
$ID,TP200
MAIN,4.21*09
GET_INSTRUMENT_STATUS:
TS,
n
Battery Voltage OK:
0
Battery Voltage below Warning Level (2.15V)
2