Section 8 – Serial Data Interface
Page 31
Height (HT) Download Messages
$PLTIT,HT
,HTvalue,units,*csum
<CR><LF>
where:
$PLTIT,
is the Criterion message identifier.
HT,
Height
message
type.
HTvalue,
Calculated Height. Two decimal places.
units,
F=feet
Y=yards
M=meters
Note: Only International lasers include meters.
*csum
An asterisk followed by a hexadecimal checksum.
The checksum is calculated by XORing all the
characters between the dollar sign and the asterisk.
<CR>
Carriage
return.
<LF>
Optional linefeed.
Example:
HD
Measurement:
$PLTIT,HV,16.00,F,0.00,D,-1.20,D,16.00,F*49
Ang_1
Measurement:
$PLTIT,HV,,,0.00,D,-19.10,D,,*73
Ang_2
Measurement:
$PLTIT,HV,,,0.00,D,32.40,D,,*52
Calculated
Height:
$PLTIT,HT,15.70,F*0E
Note: Only International lasers include meters.
HTvalues always include two decimal places:
X X.YY
0 = HD was measured to a high quality target
1 = HD was measured to a low quality target
Examples:
High Quality Target: $PLTIT,HT,5.50,M*36
Low Quality Target: $PLTIT,HT,2.01,M*35