Func
Code
Name
Range
Min
Unit
Factory
Default
Modify
P9.09
Muti-function terminal
filtering time
Range
:
0
4
~
1
1
○
P9.10
Braking unit use rate
0
100.0%
~
0.1%
30.0%
○
P9.11
Overpressure
threshold value
0
780V
~
1V
780V
○
P9.12
Energy consumption
braking bus bar
voltage
0
780V
~
1V
640V
Or 358V
○
P9.13
G/P type setting and
single-phase motor
type selection
Unit’s digit:
0: G type 1:P type
Ten’s digit: reserved
Hundred’s digit: reserved
Thousand's digit: Single-
phase motor type:
0: ordinary three-phase
asynchronous
motor(220V)
1: single-phase
asynchronous motor
(removing capacitor)
2: Single-phase
asynchronous motor
(without removing the
capacitor)
0000
0000
○
P9.14
User password
1
9999
~
1
0
○
PA Group: Vector control parameter
PA.00
Motor parameter Auto
tuning function
0
:
Inaction
1
:
Static auto tuning
1
0
×
PA.01
Motor rated voltage
0
400V
~
1
depends on
model type
×
PA.02
Motor rated current
0.01
500.00A
~
0.01A
depends on
model type
×
PA.03
Motor rated frequency
1
500Hz
~
1Hz
depends on
model type
×
PA.04
Motor rated rotating
speed
1
9999 r/min
~
1r/min
depends on
model type
×
PA.05
Motor poles number
2
16
~
1
depends on
model type
×
PA.06
Motor stator
inductance
0.1
5000.0mH
~
0.1mH
depends on
model type
×
Larson Electronics, LLC
Phone:
Fax: (903) 498-3364
www.larsonelectronics.com
35
of
52
VFD-1P-220.240-1HP-7A-DCM
(877) 348-9680