Edit. 03 - 06/2019
www.larius.eu
CH 200 AD
11
Current limiter enabled
Output current: min.120µA - max.150µA
Current limiter excluded
Output current: min.180µA - max 250µA
CIRCUIT BOARD
•
Connect the machine to the compressed air supply using
a suitable type tube (
H2
), it must have a internal diameter
that is not less than 8 mm and must be able to withstand
a maximum pressure of 10 bar.
The tube must be connected to the (
H3
) filter.
It is recommended that a shutter valve (ON-OFF)
be placed on the air supply line.
The humidity of the air must be less than 1 gr. of water p.p.m.
The quantity of air required depends on the operating pressure
(200-600 L/min.).
The compressor that supplies the air must be grounded sepa-
rately with its own grounding cable.
•
Connect the compressed air supply tube (
H4
) ø 10 mm to
the rear of the rack's control panel.
•
Connect the powder supply tube (
H6
) and the additional air
tube (
H7
) to the powder supply pump and to the generator
(
H5
).
•
Connect the generator to the spray booth using a ground-
ing cable (
H8
) and clamp (
H9
).
•
Connect the vent tube (
H10
) to the tank cover and the spray
booth (or to a container).
Electrostatic spray gun
•
Connect the power supply cable (
H11
) to the spray gun
and the generator.
•
Connect the powder passage tube (
H12
) to the spray gun
and the powder delivery pump.
•
Connect the additional air passage tube (
H13
) for clean-
ing the diffuser and rheophore to the spray gun and the
generator.
Triboelectric spray gun
•
If spray guns are used which employ the triboelectric paint
system, remove the tribo air outlet cap and connect the
tube (
H14
) to the tribo spray gun.
CURRENT OUPUT ADJUSTMENT µA
The electronic processing board located inside the generator
is supplied complete with a current limiter device that allows,
if necessary, increasing the current without modifying the set
voltage.
CONNECTIONS
•
Make sure the system is equipped with a grounding con-
nection
•
Ensure that the mains voltage corresponds to that indicated
on the machine's nameplate.
•
Make sure the switch is in the "0" position
.
•
Connect the machine to the mains using the dedicated
cable (
H1
).
Increase the value of current supplied only if nec-
essary. In normal working conditions with manual
spray guns it is recommended that the current
limiter be left enabled.