background image

 

94 

Troubles shooting 

 

 

 

Verify that is using  the right power cord/adapter  (DC  24-

power adapter with DC output higher than 48V, or it may damage this device. 

 

Select  the  proper  UTP/STP  cable  to  construct  the  user  network.  Use  unshielded 

twisted-pair  (UTP)  or  shield  twisted-pair  (STP)  cable  for  RJ-45  connections  that 

Category  5e/above cable  for 1000Mbps  connections.  Also be  sure that  the length  of 

any  twisted-pair connection does not exceed 100 meters (328 feet). 

 

Diagnosing  LED  Indicators:  To  assist  in  identifying  problems,  the  switch  can  be 

easily  monitored  through  panel  indicators,  which  describe  common  problems  the 

user  may  encounter and where the user can find possible solutions. 

 

If the power indicator does not light on when the power cord is plugged in, you may 

have  a  problem  with  power  cord.  Then  check  for  loose  power  connections,  power 

losses or surges at power outlet. If you still cannot  resolve  the  problem,  contact  the 

local dealer for assistance. 

 

If  the  LED  indicators  are  normal  and  the  connected  cables  are  correct  but  the 

s. 

 

95 

Appendix A

RJ-45 Pin Assignment 

 

 

RJ-45 Pin  Assignments 

 

The  UTP/STP  ports  will  automatically  sense  for  Fast  Ethernet  (10Base-T/100Base-TX 

connections),  or  Gigabit  Ethernet  (10Base-T/100Base-TX/1000Base-T  connections). 

Auto  MDI/MDIX  means  that  the  switch  can  connect  to  another  switch  or  workstation 

without changing straight through or crossover cabling. See the figures  below for straight 

through and crossover cable schematic. 

 

 

10 /100BASE-TX Pin outs 

 

With10/100BASE-TX cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 

for  receiving  data. 

 

 

RJ-45 Pin Assignments 

Pin Number 

Assignment 

Tx+ 

Tx- 

Rx+ 

Rx- 

 

[NOTE] 

-

 

 

The table  below shows  the 10/100BASE-TX MDI and MDI-X port pin outs. 

Pin Number 

MDI-X Signal Name 

MDI Signal Name 

Receive  Data  plus (RD+) 

Transmit Data plus (TD+) 

Receive  Data  minus  (RD-) 

Transmit Data minus (TD-) 

Transmit Data plus (TD+) 

Receive  Data plus (RD+) 

Transmit Data minus (TD-) 

Receive  Data  minus  (RD-) 

 

Summary of Contents for IPES-3408 Series

Page 1: ...r help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 1 Chapter 1 Introd...

Page 2: ...l Red Ethernet port Link Activity Green Speed Green Mini GBIC Link Activity Green Power Supply 48 56VDC Redundant power input with 1500VDC isolation 48VDC is single power input Power Consumption 10Wat...

Page 3: ...vise its identification and capability on the LAN 5 CDP Cisco Discovery Protocol for topology mapping PoE Management PoE Detection to check if PD is hang up then restart the PD PoE Scheduling to On OF...

Page 4: ...ll of packet type Ingress filter packet type combination rules are Broadcast Multicast Flooded Unicast packet Broadcast Multicast packet Broadcast packet only and all types of packet The packet filter...

Page 5: ...ng of 128 byte assigned as its own unique name via the SNMP or CLI interface 9 Chapter 2 Hardware Description information and wiring installation 2 1 Physical Dimension 65 W x 105 D x 152 H mm 2 2 Fro...

Page 6: ...n of the LED status and their meanings for the switch LED Color Status Meaning PWR Green On The switch unit is power on Off No power PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green...

Page 7: ...ht up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable cate...

Page 8: ...ow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rea...

Page 9: ...WG 17 3 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the switch will detect the fault stat...

Page 10: ...itch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the s...

Page 11: ...ransceiver please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pu...

Page 12: ...v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 is the standard protocol which can interact amongst different brands without being tie up by the same supplier to ensure...

Page 13: ...24 Multiple Rings 2 1 Dual Rings 2 2 Multiple Rings Dual Homing 25 Chain 4 1 Single Chain 4 2 Multiple Chains 4 3 Multiple Chains Share Common Ends 4 4 Cascade Chain...

Page 14: ...5 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation...

Page 15: ...configuration and functions of the Web Based management 6 1 About Web based Management There is an embedded HTML web site residing in flash memory on CPU board of the switch which offers advanced mana...

Page 16: ...name A domain name is a text string drawn from the alphabet A Za z digits 0 9 minus sign No space characters are permitted as part of a name The first or last character must not be a minus sign The a...

Page 17: ...IPV6 standard of switch in here Network Mask The network mask of IP address Default Gateway The IP address of network gateway if you need switch to connect with internet please input correct IP addres...

Page 18: ...ence 35 Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight...

Page 19: ...Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight Clock Source You can set Manual to set the time of switch manually or set...

Page 20: ...r Both Authentication Protocol Set the authenticated way the default value was MD5 Authentication Password Set the password of authentication Privacy protocol Set the security way the default value wa...

Page 21: ...og Server Save log to Syslog Server Email Action Email Alert Sent log via Email 41 SMS Action SMS Alert Sent log via SMS service The user must let the switch connect with internet and define the SMS s...

Page 22: ...y the host computer They provide messages which can be applied to heaters pumps and other electrical equipment The digital inputs may be read by the host computer and used to sense the state of a remo...

Page 23: ...lectrical signal of Low to High when the condition of the ticked checkbox is met port power failure occurs 6 4 8 Environment Monitoring Environment Monitoring You can see the hardware status of switch...

Page 24: ...rces the cu port in 100Mbps full duplex mode 1Gbps FDX Forces the cu port in 1Gbps full duplex mode 6 5 2 Port Status 47 Port No This is the logical port number for this row Type This is the logical p...

Page 25: ...th RX and TX traffic which come from source port Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port 49 Port Rate Limiting You can set...

Page 26: ...aximum power available the switch will offer the power to the high priority PoE port and stop to supply power to the low priority PoE port Power Limit Set the Maximum power of each PoE port 51 Power C...

Page 27: ...switch 53 6 7 Topology This function can help the user build the network topology drawing of field in switch please remember to enable LLDP function before you using this application Topology Status...

Page 28: ...54 Graphic View Display each switch in your network by graphic You can see the topology diagram which build by the LLDP information in here 55 Demo Demo display each topology in different application...

Page 29: ...level 25 is 7 The port 1 is following the ToS priority policy 57 only When the packet received by port 1 the system will check the ToS value of the received IP packet If the ToS value of received IP...

Page 30: ...IP address which you want to deny Mask set the mask to filter the IP range 59 6 9 3 IEEE 802 1X Radius Server 802 1X makes use of the physical access characteristics of IEEE802 LAN infrastructures in...

Page 31: ...e the switch through the Web browser 61 6 10 VLAN The VLAN membership configuration for the switch can be monitored and modified here Up to 4094 VLANs are supported This page allows for adding and del...

Page 32: ...ross switches PVID Indicates the VLAN ID of this particular VLAN Tagged VID This column field is available when Link Type is set as Trunk Link and Hybrid Link Assign a number in the range between 1 an...

Page 33: ...d from neighbors but will send out LLDP information Disabled The switch will not send out LLDP information and will drop LLDP information received from neighbors Both The switch will send out LLDP inf...

Page 34: ...Many Neighbours in the LLDP standard LLDP frames require a new entry in the table when the Chassis ID or Remote Port ID is not already contained within the table Entries are removed from the table whe...

Page 35: ...Value If a TLV is malformed it is counted and discarded TLVs Unrecognized The number of well formed TLVs but with an unknown type value 69 6 13 IGMP Snooping This page provides IGMP Snooping related...

Page 36: ...ted stack unit as reflected by the page header Statistics VLAN ID The VLAN ID of the entry 71 Status Querier Shows the Querier status is ACTIVE or IDLE DISABLE denotes the specific interface is admini...

Page 37: ...formation about how long the information in the CDP frame shall be considered valid The holdtime between each CDP frame is determined by the Tx Holdtime value Valid values are restricted to 5 32768 se...

Page 38: ...for higher layer entities to assist discovery by the network management This could for instance hold the neighbor s IP address 75 6 14 MSTP 6 14 1 MSTP Global Configuration Mode You can choose STP or...

Page 39: ...region It defines how many bridges a root bridge can distribute its BPDU information to Valid values are in the range 6 to 40 hops How to enable MSTP 6 14 1 1 Enter MSTP CIST Settings press icon to en...

Page 40: ...e port priority This can be used to control priority of ports having identical port cost See above edge_mode Controls whether the operEdge flag should start as being set or cleared The initial operEdg...

Page 41: ...on the least cost path to the Root Bridge Topology State The current state of the Topology Change Flag of this Bridge instance Topology Change Last The time since last Topology Change occurred 81 6 1...

Page 42: ...3 6 15 2 LACP Port Status Trunking Group Number of trunking group LACP Yes means that LACP is enabled and the port link is up No means that LACP is not enabled or that the port link is down Backup mea...

Page 43: ...give a specific switch priority over other identical switches The range for both is from 0 to 255 The default is 255 Announce Interval Specify the time for sending announce messages The range is 0 to...

Page 44: ...1 2 Press icon to add one ring with G 8032 protocol PS in this case we will use the port9 and port10 of each switch to build a ring 87 6 16 1 3 Enter edit mode 6 16 1 4 There are 3 switches in the rin...

Page 45: ...ID The ID of the created Protection group State ERPS state according to State Transition Tables in G 8032 Role It can be either RPL owner or RPL Neighbour Ring Port 0 true ring port 0 is blocking fal...

Page 46: ...he switch to the startup configuration on this page The new startup configuration is not available immediately which means that restart the switch is necessary 91 Reset to default You can reset the co...

Page 47: ...e file which on your desktop 6 18 5 Diagnostics PING Address Set the IP address which you want to ping Count Set the times of Ping Packet Size set the size of Ping packet 93 ARP Table You can find the...

Page 48: ...still cannot resolve the problem contact the local dealer for assistance If the LED indicators are normal and the connected cables are correct but the s 95 Appendix A RJ 45 Pin Assignment RJ 45 Pin A...

Page 49: ...se TX cable schematic Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs 10 100 1000Base TX Cabl...

Page 50: ...ation parameters to match the following default characteristics of the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters O...

Page 51: ...ket was set as 23 all the commands under Telnet mode were the same as the Console mode 3 Commands 3 1 System Command system Parameter N A Description Enter the system mode Example 101 3 1 1 Command sy...

Page 52: ...1 5 Command system description Parameter N A Description display or fix the system description Example 103 3 1 6 Command system DHCPclient Parameter enable disable Description enable or disable DHCP c...

Page 53: ...v6 Example 105 3 1 12 Command system reboot Parameter N A Description reboot the switch Example 3 1 13 Command system restoredefault Parameter keep_none restore all setting keep_all restore all but ke...

Page 54: ...t import export or import the setting of switch URL set the destination which save load the setting file support both the TFTP and FTP protocol Description export or import the setting of switch Examp...

Page 55: ...th dedicated port enabledRxOnly enable Rx only of LLDP function with dedicated port disabled disable LLDP function with dedicated Description enable LLDP function of each port Example 109 3 2 4 Comman...

Page 56: ...settings Example 3 3 Port Command port Parameter N A Description Enter the port mode Example 111 3 3 1 Command port configuration Parameter N A Description display the setting of each port Example 3 3...

Page 57: ...mand port description Parameter N A Description display the description of each port Example 113 3 3 5 Command port speed Parameter N A Description display the speed of each port Example 3 3 6 Command...

Page 58: ..._uni uni_broad_multi Description set the ingress rate of the dedicated port with specified packet Example 115 3 3 8 Command port egressrate Parameter port_list choose which port you want to set the in...

Page 59: ...116...

Reviews: