![L&W SC-600 ES Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/landw/sc-600-es/sc-600-es_operating-instructions-manual_4562516023.webp)
LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Page A - 21
A
Fig. Ventilation through facade
Fig. Ventilation via ventilation stack
I N S T A L L A T I O N
Ventilation
• Make sure that the compressor always has a sufficient amount of fresh air available for cooling.
• To prevent serious damage, ensure that the cooling air flow can flow freely.
• The necessary cooling air flow can be calculated by using the following formula:
300 x drive power [kW] = required cooling air flow [m³/h]
Example 11kW motor: 300 x 11kW = 3300 m³/h = required cooling air flow.
• The fan capacity for fresh air and warm air must meet at least the required cooling air flow.
The fans must have the same capacity.