LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Page A - 18
A
I N S T A L L A T I O N
Installation in closed rooms
For installation in closed rooms, observe the following:
• Install the unit horizontally and level. The floor must be vibration-free and capable of taking the
load of the system weight.
• The compressor room must be clean, dry, dust free and as cool as possible. Avoid direct exposure
to sunlight. If possible, install unit in such a manner that the compressor fan can intake fresh air
from outside. Ensure adequate ventilation and exhaust air opening.
• When locating the compressor in rooms of less than 30 m³ space where natural ventilation is not
ensured or other systems having high radiation are operating in the same room, measures must
be taken to provide artificial ventilation.
• Intake air must be free from noxious gas e.g. smoke, solvent vapours, exhaust fumes etc.
• Observe the specified operating temperature (see "Technical Data")!
Danger
No operation in explosion-hazard areas.
The unit is not approved for operation in areas prone to explosion.
!
Note
The intake air must be free of harmful gases.
We recommend to use an intake hose in order to get fresh air from the outside.
i
Pos.
Length of suction hose [m]
Diameter suction hose [mm]
1
≤ 3
Ø 30
2
≤ 10
Ø 80
3
≤ 15
Ø 100
4
≤ 20
Ø 120
Summary of Contents for SC-600 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 600 ES LW SC 680 ES LW SC 750 ES...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...C Version 20 11 2023 ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 132: ...E A T T A C H M E N T Version 11 12 E...
Page 136: ...INFORMATION ON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 144: ...ANNEX...