Configuration
item
Description
Default
configuration
Unit / Type
Remotely
configurable
via DCC
Payment Mode
Payment
Mode
The payment mode in operation on
the meter which is either Credit or
Prepayment.
Credit Mode
Credit/
Prepayment
Yes
Tariff and Charges Settings
Currency
Units
The currency units currently used by
the meter, which shall be either GB
Pounds or European Central Bank
Euro
GB Pounds
GBP/Euros
Yes
Tariff Matrix in
Use
The type of tariff matrix that is active
on the meter at point of
manufacture, either Tariff TOU
Register Matrix or Tariff TOU Block
Register Matrix
Tariff Time of
Use Register
Matrix
Tariff ToU
Register Matrix or
Tariff TOU Block
Register Matrix
Yes
Number of
Rates and
Blocks
The number of rates configured (if
TOU only) or the number of rates
and blocks (if TOU with Block tariff).
Single rate
Number of rates
or rates and
blocks
Yes
Tariff Rate
The Active tariff price per kWh
£0.00
currency per kWh
Yes
Standing
Charge
The charge to be levied per unit of
time on the meter (credit and
prepayment mode)
£0.00
currency per unit
time
Yes
Season Profile The season table allows definition of
up to 4 seasons. It defines, for each
season, the week profile to be used
during that part of the year.
Single season
across the
year
OCTET-STRING
defining up to 4
seasons and
associated week
tables
Yes
Week Profile
The week table defines which Day
Profile to be used on each of the
days of the week.
The same day
profile
allocated on
each of the
days Monday
to Sunday
INTEGER defining
the day table to be
used on each day
of the week
Yes
Day Profiles
The Day table defines how
consumption is allocated to tariff
registers and switching points to be
used throughout a day profile. Up to
16 tariff day profiles can be defined.
Single day
profile
specifying a
single rate to
be used
throughout
the day
Table Identifier
Yes
Special Days
Up to 50 tariff special days can be
defined either specific dates in the
year or recurring dates using
wildcards
Array of Zero
Entries (no
special days
defined for
the tariff
calendar)
Dates including
wildcards/day
profile identifier
Yes
Prepayment Settings
Emergency
Credit
Threshold
The threshold in currency units
below which Emergency Credit may
be activated, when the meter is
operating in Prepayment Mode
£0.00
Currency units
Yes