Operation
29/52
D000030875 en q
– E350 series 2, 1-phase ZCF100Ax/Cx – User Manual
© Gyr
5.2.5
Display Sequence
The previous section showed in detail the possible displays. The display
sequences shown on any specific customer’s product are set through
parameterisation at the factory.
There are two display sequences:
Main display
(with an auto scrolling list and a recall list)
Service display
(with the service list)
The main display can include up to 31 displays, the service display up to 63
displays (defined by parameterisation).
The parameters which have an influence on the display sequence must be
defined in the configuration process.
These items are:
Leading zeros can be enabled/disabled for registers.
Energy register displays can be defined with an integer part of 6 digits
(in exceptional cases 5) and with 0, 1, 2 or 3 decimal places. Max 6
significant digits (left of the decimal point) are allowed. Max. 8 digits
including decimal places are available.
Only 6 integer digits are allowed for meters according MID.
Active rate indication can be enabled or disabled.
Flashing decimal point in the energy register displays to indicate that
the meter is in the service or certification display sequence.
= short press of display button (< 5 s)
= long press of display button (> 5 s)
Main display
Recall list
Value 2
Consumption since reset
Reset of
register
Service list
Value 5
Value 6
Service display
Value 2
Value 3
Value 1
Value 4
Auto scrolling list
Value 2
Meter start
(power up)
Value x
Value 1
Value 3
Value n
Value y
Fig. 5.4 Overview display sequences