Appliance description

Adjustable feet

Hanging System

Dimensions

Width: 900 mm
Depth: 900 mm

Height with ceiling unit:  
•  LU 10000

®

 Premium 2400 mm

•  LU 11000

©

 Premium 2790 mm

Height with side unit:
•  LU 10000

®

 Premium 2100 mm

•  LU 11000

©

 Premium 2490 mm

2 hanging rails and outer 

loading bar

height adjustable

Control element

For information on temperature setting,

 see page 5

For function of loading bar  

see page 15

Rating plate

Setting up

The ground at the location should be horizontal and level. Level 
out any unevenness using the adjustable feet. The back of the 
appliance can be placed directly against the wall. Ensure good 
ventilation!

Dismountable version

The LU 11000

©

 Premium is supplied unassembled due to its 

height. The appliance is then set up on site on a level floor 
(work very precisely and cleanly!).

Important: 

 A silicone joint should be made on the dismount-

able appliance at the connection between the wall element 
and floor element on the ground using a transparent food-safe 
silicone (included in scope of delivery).

Cooling machines – assembly with ceiling cooling:

Always have two people put the machine in the designated cut-
out in the ceiling so that the controller points forwards in the 
direction of the doors; set the machine down – that’s it! Further 
fixing using screws etc. is not necessary.

Cooling machines – assembly with side wall cooling:

Always use two people to assemble the machine. Turn the 
supplied threaded bolts approx. 1-2 cm into the machine, then 
carefully fix the machine together with the bolts to the wall and 
attach it from the inside with washers and nuts. You can find 
details of this on page 14.

The appliance is now ready for operation. Insert the mains plug 
into an earthed socket (220 V, 16 amps, fused). Note: the elec-
tronic compressor control switches on the compressor itself 
after the switch-on delay of 5 minutes.

Alignment

Move the appliance at the installa-
tion site to its final position.

Level out any unevenness on the 
ground with the adjustable feet.

IMPORTANT

The appliance must be aligned horizontally and 

vertically. If the appliance is at an angle, the body of 

the appliance may be deformed and the door does 

not shut correctly.

 

WARNING

The adjustable feet are adjustable in height  

from 83 mm to 120 mm. Do not adjust the adjust-

able foot above a height of 130 mm! The lower 

part of the adjustable foot may loosen and tip  

the appliance over. This can lead to serious  

or fatal injuries.

Operating and control elements

Explanation of keys

Cooling outlet
Alarm
Info key / setpoint adjustment 
Key parameters DOWN
Key parameters UP
Key back

Displays

DEF

  Defrosting in progress

REC

  Return to setpoint after defrosting

HI

  Overheating alarm in the cell

LO

  Insufficient temperature alarm in the cell

E1 

Defect or exceeding / undershooting the 

 

measurement range of sensor T1

LOC

 State of the key lock

Setting the temperature 

The cooling system is equipped with an electronic control 
system which can display the target and actual temperature. 
After reaching the pre-selected temperature, the cooling unit 
switches off and only the recirculation fan in the refrigerator 
continues to run.

The appliance can also be plugged in only as required with 
non-permanent operation and then ensures that the set tem-
perature is achieved in a short amount of time with a suitable 
room size.

The required temperature can be conveniently set on the elec-
tronic controller.

Recommended temperatures

Roe deer / fallow deer / red deer:

 +1 °C to +4 °C 

Wild boars: 

+1 °C to +2 °C

Brown hares / rabbits: 

+1 °C to +4 °C

In general the following applies:

 

max. recommended storage temperature is 

10 days at +1 °C. 

Altering the setpoint

Hold down the 

 key to display the setpoint. Hold down the 

 key to alter the setpoint and also set the desired value with 

the keys 

 or 

. The desired setpoint is saved once you 

release the 

 key.

Key lock

A key lock can be programmed to prevent unauthorised ac-
cess. To do this, press the key 

  several times in succession 

until 

LOC

 appears in the display. Then hold down the key 

 

and use one of the two arrow keys 

 or 

 to change from 

NO

 to

 YES

. The key lock is active once you have released the 

 key and the setpoint can no longer be altered. Change the 

value to 

NO

 again to deactivate the key lock.

Defrosting

The refrigerator compartment defrosts automatically. The 
moisture that accumulates is fed into an evaporator tray via 
the condensation drain integrated in the machine. The conden-
sation evaporates there due to the compressor heat.

Please note for large amounts of condensation: there is a con-
densation overflow pipe at the front of the cooling unit. This 
connection is used (unscrew screw at the front) if the con-
densation evaporator tray in the appliance is overflowing.  An 
on-site drain (for example, plastic tube) can then be connected 
to this pipe to drain off the condensation.

Decommissioning

When the appliance is taken out of operation for a prolonged 
period: switch off the appliance, disconnect the power plug 
from the mains or trip/unscrew the upstream fuses. Clean 
the appliance and leave the door open to avoid a build-up of 
odours.

The appliance meets the relevant safety regulations and EC 
directives 2004/108/EC and 2006/95/EC.

Security lock

The lock is equipped with a safety mechanism. 

Locking the appliance

1. Push the key in in direction 1.
2. Rotate the key by 180°.

Proceed in the same order to unlock the appli-
ance again.

Summary of Contents for LU 10000 PREMIUM

Page 1: ... fürechtejäger DE LU 10000 PREMIUM LU 11000 PREMIUM WILDKÜHLSCHRÄNKE Bedienungsanleitung EN Instructions for use PROFESSIONAL GAME FRIDGE ...

Page 2: ...rlegtes Wild selbst zu Hause mit dem Landig Wildkühlschrank Drei geschützte Technologien im Gerät sorgen für ein perfektes Ergebnis ohne Vorkenntnisse und zusätzlichen Aufwand Profitieren Sie unter anderem von einem schnellen Abkühlen einem verringerten Gewichtsverlust und der Möglichkeit einer längeren Reife und Lagerzeit Wildbret zarter Genuss aus der Natur Wild ist vielseitig und hat viele posi...

Page 3: ...Übertemperaturalarm in der Zelle LO Untertemperaturalarm in der Zelle E1 Defekt oder ein Über oder Unterschreiten des Messbereichs des Fühlers T1 LOC Zustand der Tastensperre Temperatur einstellen Das Kühlsystem ist mit einer elektronischen Steuerung aus gestattet welche die Soll und Ist Temperatur anzeigen kann Nach Erreichen der vorgewählten Temperatur schaltet sich das Kühlaggregat aus und nur ...

Page 4: ...n Gebrauch oder durch unsachgemäße Behandlung zur Beeinträchtigung des Aussehens der Oberflächen kommen Mit der Verschmutzung erhöht sich gleichzeitig die Korrosions belastung und die Bauteile können langfristig geschädigt wer den Eine Reinigung ist notwendig um den wertigen Edelstahl Look zu erhalten durch Schmutzbeseitigung die Korrosionsbelastung zu verringern Bei Edelstahl können unterschiedli...

Page 5: ...8 9 EN Instructions for use LU 10000 PREMIUM LU 11000 PREMIUM PROFESSIONAL GAME FRIDGE EN Instructions for use ...

Page 6: ...rdance with the information contained in the instruction manual in order to ensure safe operation Disconnect the appliance from the mains if there is a fault Unplug from the mains or trip unscrew the fuse Do not pull on the connecting cable but rather on the plug to disconnect the appliance from the mains Repairs and interventions on the appliance may only be car ried out by the customer service r...

Page 7: ...ck Displays DEF Defrosting in progress REC Return to setpoint after defrosting HI Overheating alarm in the cell LO Insufficient temperature alarm in the cell E1 Defect or exceeding undershooting the measurement range of sensor T1 LOC State of the key lock Setting the temperature The cooling system is equipped with an electronic control system which can display the target and actual temperature Aft...

Page 8: ...n metal work are subject to natural atmospheric contamination due to weathering More over normal use or improper treatment can negatively impact the appearance of the surfaces With contamination exposure to corrosion increases at the same time and the components can be damaged in the long term Cleaning is necessary to maintain the valuable stainless steel look reduce exposure to corrosion by remov...

Page 9: ...0x 50x 2x 4x optional 4x 1x 1x 08 2018 01 08 1x 4x 50x 50x 2x 4x optional 4x 1x 2x 1x 08 2018 01 08 1x 50x 50x 2x 4x optional 4x 1x 1x 1x 1x 1x 08 2018 01 08 1x 4x 50x 50x 2x 4x optional 4x 1x 1 2 3 3x 1x 1x 08 2018 01 08 1x 4x 50x 50x 2x 4x optional 4x 1x 1x 08 2018 01 08 1x 4x 50x 50x 2x 4x optional 4x 1x 1x 08 2018 01 08 1x 4x 50x 50x 2x 4x optional 4x 1x 1x 1x 1x 1 2 3 3x 1 2 3 3x 1 2 3 8x 3x ...

Page 10: ...18 19 4 5 6 4 5 6 3x 08 2018 03 08 3x 4 5 6 4 5 6 3x 08 2018 03 08 3x 8x 3x 4 5 6 08 2018 03 08 18x 3x 7 8 3x a b 7 8 3x a b 7 8 34x 34x 14x 3x ...

Page 11: ...20 21 4x a b 9 10 4x 9 10 a 11 12 Option I Option II a 11 12 Option I Option II 11 12 3x a b 11 12 Option I Option II 3x Option I Option II ...

Page 12: ... without chain secured to ceiling as this can cause your game fridge to tip over and increase the risk of injury Option Sicherheits Warnhinweis zur Rohrbahn Benutzung Die bei der Außenschiene mitgelieferte Kette muss an der bauseitigen Decke an einem belastbaren Punkt mindes tens 200 kg Tragkraft fixiert werden dass die Außen schiene im aufgesteckten Zustand aufgrund des hohen Gewichts durch das E...

Page 13: ...ebook com landig wildkuehlung www instagram com landig wildkuehlung Art Nr WZ0010 Landig Lava GmbH Co KG Mackstraße 90 88348 Bad Saulgau Germany Telephone 49 7581 90430 Email info landig com Web www landig com ...

Reviews: