6. Wash thoroughly with cleaning solution.
7. Rinse thoroughly with warm water and replace.
8.
Using a funnel, fill the specially-marked sanitizing container
to the top with cool sanitizing solution. place sanitizing
container in dispenser.
9. Place check valve in sanitizing container.
10. Press the
*
button for two minutes ensuring concentrate lines
are full of solution. Let solution stand for five minutes without
dispensing.
11. For each valve, perform a second two-minute dispense and
let stand for an additional five minutes.
12. Press the
*
button until the sanitizing solution empties from
the sanitizing container.
13. Remove check valve from sanitizing container, remove
sanitizing container, and pour out any sanitizing solution that
remains in the container. Repeat for each valve.
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
15. Using the
*
button, run the pump until only concentrate is
dispensed, to remove traces of sanitizing solution from the
dispenser.
16. Remove drip tray and cup rest. Wash thoroughly with
cleaning solution. Rinse thoroughly with warm water.
17. Wipe the dispenser with a clean, damp cloth, taking care to
remove all product residue.
18. Replace drip tray, and cup rest.
19. Return key to
ON
position.
20.
Pour approximately two ounces of finished drink product to
fill nozzle.
14. Reinstall Minute paks®, and connect check valves in