INSTALLATION
Unpack the Dispenser
If unit is to be transported, it is advisable to leave the
unit secured to the plywood shipping base.
NOTE
Inspect unit for concealed damage. If evident, notify
delivering carrier and file a claim against the same.
NOTE
Selecting/Preparing Counter Location
1. Select a level, well ventilated location that is in close
proximity to a properly grounded electrical outlet, within five
(5) feet (1.5 m) of a drain, a water supply that meets the
requirements shown in the Specifications section found on
pages 2, and away from direct sunlight or overhead lighting
2. The selected location should be able to support the weight of
the dispenser with ice bank after counter cut out is made.
Total weight (with ice bank) for this unit could exceed 400
pounds (181.4 kg).
The dispenser should only be installed in a location
where it can be overseen by trained personnel
NOTE
Install on supplied legs only. DO NOT seal to
countertop. Condenser air is drawn from the bottom of
the dispenser and exhausted out of the back.
2-VALVE
Unit may be installed directly on countertop or on legs.
If installed directly on the counter, unit must be sealed
to the countertop with an FDA approved sealant.
4-VALVE
In order to facilitate proper dispenser drainage, ensure
that the dispenser is level, front to back and side to
side. Place a level on the top of the rear edge of the
dispenser. The bubble must settle between the level
lines. Repeat this procedure for the remaining three
sides. Level unit if necessary. For optimum perfor-
mance place the unit at a 0° tilt. The maximum tilt is 5°.
Leveling the Dispenser:
NSF listed units must be sealed to the counter or have
four (4) inch legs installed.
NOTE
To assure that beverage service is accessible to all
customers, Lancer recommends that counter height
and equipment selection be planned carefully. The
2010 ADA Standards for Accessible Design states that
the maximum reach height from the floor should be no
more than 48” if touch point is less than 10” from the
front of the counter, or a maximum of 46” if the touch
point is more than 10” and less than 27” from the front
of the counter. For more information about the
customer’s legal requirements for the accessibility of
installed equipment, refer to 2010 ADA Standards for
Accessible Design - http://www.ada.gov.
NOTE
To avoid personal injury or damage, do not attempt
to lift a unit without help. For heavier units, use of a
mechanical lift may be appropriate. Units are equipped
with automatic agitation. The unit may activate
unexpectedly. Do not place hands, or foreign objects
into the ice storage compartment. Unplug dispenser
from the power source , when unit is being serviced,
cleaned, or sanitized.
!
WARNING
1. Remove outer packaging.
2. Slide a corner of the dispenser (on plywood shipping base)
over the edge of the counter and remove shipping screw and
washer.
3. Replace shipping screw and washer with a 3/8” x 16
stainless phillips truss head from installation kit.
4. Repeat for remaining corners.
5.
Slide dispenser off of plywood shipping base.
DO NOT LAY UNIT ON ITS SIDE OR BACK.
!
ATTENTION
6. If a leg kit has been provided, assemble legs by tilting unit.
Failure to maintain specified clearance will cause the
compressor to overheat and will result in compressor
failure
!
ATTENTION
3. Ensure the location provides a minimum of four inches of
clearance on the sides and back of the dispenser.
4. Ensure proper ventilation as follows:
5. If the unit is to be installed directly to counter, cut the
necessary holes in counter for water and electrical line in the
designated dispenser location.