Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must 

be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimum of 35 PSI (0.241 MPA) line pressure, but not exceeding a maximum of 90 PSI (0.621 MPA).  

Water pressure exceeding 90 PSI (0.621 MPA) must be reduced to 90 PSI (0.621 MPA) with the provided pressure regulator. Use 

a filter in the water line to avoid equipment damage and beverage off-taste. Check the water filter periodically, as required by local 

conditions. The water supply must be protected by means of an air gap, a backflow prevention device or another approved method 

to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to flow back through the pump when it 

is shut off and contaminate the water supply. Ensure the backflow prevention device complies with ASSE and local 

standards. It is the responsibility of the installer to ensure compliance.

Water Notice

SPECIFICATIONS

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Numer:

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this 

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 35 PSIG (0.241 MPA)

 

Max Flowing Pressure

: 90 PSIG (0.621 MPA)

FITTINGS

 

Plain Water Inlet

: 3/8 inch barb

ACCESSORY

 

82-3789: 

Drop Down Drip Tray

DIMENSIONS

 

Width

: 10.13 in (257 mm)

 

Depth

: 25.5 in (648 mm)

 

Height

: 33 in (838 mm)

WEIGHT

 

Shipping

: 125 lbs (56.7 kg)

 

Empty

: 112 lbs (50.8 kg)

 

Operating

: 160 lbs (72.6 kg)

ELECTRICAL

 

115 VAC / 60 Hz / 7.0 Amps

REFRIGERATION

 

Motor

: 1/4 hp Compressor

 

Type

: R134a

 

Ice Bank Weight

: 10.0 lbs (4.54 kg)

 

Ice Bank Capacity

: 4.5 g (17.0 L)

2-Valve Dispenser

This unit emits a sound pressure level below 70 dB

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 35 PSIG (0.241 MPA)

 

Max Flowing Pressure

: 90 PSIG (0.621 MPA)

FITTINGS

 

Plain Water Inlet

: 3/8 inch barb

ACCESSORY

 

82-3751: 

Drop Down Drip Tray

DIMENSIONS

 

Width

: 18.06 in (458 mm)

 

Depth

: 26.25 in (667 mm)

 

Height w/o legs

: 29.63 in (752 mm)

 

Height with legs

: 33 in (838 mm)

WEIGHT

 

Shipping

: 170 lbs (77.3 kg)

 

Empty

: 140 lbs (109.1 kg)

 

Operating

: 305 lbs (138.6 kg)

ELECTRICAL

 

115 VAC / 60 Hz / 7.0 Amps

REFRIGERATION

 

Motor

: 1/3 hp Compressor

 

Type

: R134a

 

Ice Bank Weight

: 21.0 lbs (9.55 kg)

 

Ice Bank Capacity

: 6.5 g (24.6 L)

4-Valve Dispenser

This unit emits a sound pressure level below 70 dB

Summary of Contents for Minute Maid

Page 1: ...play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons including children with reduced physical sensory or menta...

Page 2: ...the owner operator and installer of this dispenser Please read this guide before installation and operation of this dispenser If service is required please call your Lancer Service Agent or Lancer Cu...

Page 3: ...ed NOTE To assure that beverage service is accessible to all customers Lancer recommends that counter height and equipment selection be planned carefully The 2010 ADA Standards for Accessible Design s...

Page 4: ...nk In order to optimize the maximum performance of the dispenser the following MUST be adhered to CRITICAL to maximize performance For proper function of the electronic ice bank control the total diss...

Page 5: ...n of the equipment grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow strips is the equipment groundi...

Page 6: ...achine dispensing nozzle and press the PUSH button until a clear stream is observed 3 Purge the remaining valves the same way progressing to your right 4 Turn the key back to the ON position 5 Dispens...

Page 7: ...Water will pour automatically Note level of water 4 The poured sample should be 450 ml If sample is off by more than 10 ml troubleshoot the water sub system Discard water sample 5 Replace cylinder un...

Page 8: ...the unit DO NOT disconnect water lines when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT...

Page 9: ...anitizing container and pour out any sanitizing solution that remains in the container Repeat for each valve Following sanitization rinse with end use product until there is no aftertaste Do not use a...

Page 10: ...ing Diagram SOL 2 FM 2 CAL 2 CAL 1 1 SOL 1 FM P1 P2 REAR S O DISPLAY 24 VDC F1 CPU KEY SW DR BD LT BD CAB FAN AGITATOR DECK PWR SUPPLY BD MTR 1 MTR 2 SO SO 1 2 AC IN GR WHT BLK GR BLK WHT BOX FAN CPU...

Page 11: ...improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrigerant and i...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: