THE

 

 

 

 
 
 

 

 
 

BOILING WATER DISPENSER 

INSTALLATION & OPERATING INSTRUCTIONS 

 

 
 
 
 
 
 
 

 

IMPORTANT: 

This booklet should be left with the user after 

installation and demonstration

 

Summary of Contents for Professional SB

Page 1: ...9JJ UK Telephone 44 0 844 372 7761 Fax 44 0 84 372 7762 Website www applied energy com Technical Advisory Service Hotline 44 0 844 372 7766 THE BOILING WATER DISPENSER INSTALLATION OPERATING INSTRUCTIONS IMPORTANT This booklet should be left with the user after installation and demonstration ...

Page 2: ...13A plug however this product is not to be classed as a portable appliance and as detailed on page 3 it is instructed that the unit is to be wired to a means for disconnecting the fixed wiring in all poles in accordance with the wiring rules eg 13A fused double pole isolating switch In the unlikely event that the unit is fitted incorrectly the recommendation is if test is carried out with water in...

Page 3: ...urrent BS 7671 IEE Wiring Regulations and the Water Fittings Regulations Local regulations may apply in other countries The steam vent connection MUST BE MADE as required in these instructions A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules Check that the mains supply matches the electrical rating on the product The rating plate i...

Page 4: ... top edge of the unit Disconnect the neon light carefully unclipping it from the front cover 9 Maintenance Descaling Process To Drain the unit Turn off the water and electricity power supplies Turn on the tap on the front of the unit to drain the tank Unscrew and remove the tap and remove 4 fixing screws on outer cover Shield the electronic controller from possible water damage Carefully remove th...

Page 5: ... a MANUAL RESET SAFETY DEVICE which operates in a BOIL DRY situation and a MANUAL RESET THERMOSTAT for detecting excessive steam in the event of electronic controller failure or water solenoid valve failure Unless you are a qualified engineer DO NOT ATTEMPT to repair this unit yourself In the event of malfunction please contact our Technical Service Helpline on 0844 372 7766 WARNING SCALDING HOT W...

Page 6: ...The supply cable must be a minimum of 1 0mm 3 Core multi strand PVC insulated mains cable The terminal block will not accept cable diameters above 1 5mm Check that the mains supply matches the electrical rating on the product The rating plate is located on the bottom edge of the unit IMPORTANT Connect the supply cable complying with BS 6500 to this appliance in accordance with the following code G...