background image

 

Where to locate the unit 

 

 

We recommend that the unit is installed on a suitable wall, at shoulder height and over a sink. 

 

 

Adjacent to the means for disconnecting the fixed wiring in all poles in accordance with the wiring 
rules (ie: 13A fused double pole isolating switch). 

 

 

Available mains cold water supply and drainage facility. 

 

 

DO NOT install the unit within reach of a person using a bath or shower. 

 

 

This unit must not be installed in an area cleaned by a water jet. 

 

 

DO NOT obstruct the ventilation channels on the top of the cover plate. 

 

Installing the water supply and steam vent pipes 

 

The unit must be connected to cold, mains fed, drinking water only.                                                                                             
Pressure range between 0.2 MPa (2.0 bar / 29psi) and 1.0 MPa (10.0 bar / 140 psi). 

 

DO NOT connect to a storage tank 

 

 

Isolate the water supply 

 

 

Lay in the Ø15mm water supply pipe to the location of the inlet connection. 

 

 

Lay in the Ø15mm drainage pipe to the location of the steam vent connection. 

 

 

The steam vent connection must be taken directly to the sink below, if there is one,                                          
or via a tundish to a suitable drain.                                                                                                                                                                                                    
If a sink is used it must be able to withstand boiling water and have an overflow connection. 

 

Installing the mains supply 

 

If a mains supply is not already available. 

 

Install a means for disconnecting the fixed wiring in all poles                                                                         
(eg. 13A fused double pole isolating switch) adjacent to where the unit will be fixed. 

 

Removing the front cover 

 

 

Ensure unit is disconnected from mains electricity supply. 

 

 

Ensure unit is emptied of water through opening of tap and allow unit to cool. 

 

 

Unscrew the front tap. 

 

 

Remove the screws from the bottom and top edge of the unit. 

 

 

Disconnect the neon light, carefully unclipping it from the front cover. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Maintenance / Descaling Process 

 

To Drain the unit  

 

 

Turn off the water and electricity power supplies. 

 

 

Turn on the tap on the front of the unit to drain the tank. 

 

 

Unscrew and remove the tap and remove 4 fixing screws on outer cover. 

 

 

Shield the electronic controller from possible water damage. 

 

 

Carefully remove the drain plug from the bottom of the tank and drain. 

 

WARNING:  Beware of splashing water as it may be near boiling point. 

 

Descaling 

 

If scale comes out with the hot water then the unit may need to be descaled.                                           
As with all water heaters scale will build inside the tank.                                                                                    
How quickly this build up occurs will depend on the hardness of the water and the frequency 
of use. 
Please follow the procedure below:- 

 

 

A suitably qualified person should carry out the descaling. 

 

 

Ensure the mains electricity supply is isolated. 

 

 

Unscrew and remove tap. 

 

 

Remove 4 fixing screws on outer cover. 

 

 

Remove draining plug on bottom of water tank. 

 

 

After water has drained out replace plug. 

 

 

Mix 2 teaspoons (approximately 10ml) food grade citric acid into a cup of water. 

 

 

Feed citric acid through tap hole (either by funnel or placing tap half way on the thread, turning 
upside down with the tap lever permanently open). 

 

 

Tighten tap, leaving outside cover off. 

 

 

Turn power on, unit will cycle and fill. Allow unit to boil for 10 minutes then drain. 

 

 

Turn power off. 

 

 

Drain unit and remove tap. 

 

 

Replace outside cover. 

 

 

Replace tap, turn power on. 

 

 

Wait until unit has filled with water – drain once again from tap, allow unit to refill. 

 

 

Unit is ready for use. 

 

Cleaning: 

 

 

Before cleaning, switch off the electricity at the isolating switch. 

 

 

It is recommended that the unit surfaces are cleaned with a soft cloth. 

 

 

Do not use abrasive or solvent cleaning fluids. 

 
 
 
 

Summary of Contents for Professional SB

Page 1: ...9JJ UK Telephone 44 0 844 372 7761 Fax 44 0 84 372 7762 Website www applied energy com Technical Advisory Service Hotline 44 0 844 372 7766 THE BOILING WATER DISPENSER INSTALLATION OPERATING INSTRUCTIONS IMPORTANT This booklet should be left with the user after installation and demonstration ...

Page 2: ...13A plug however this product is not to be classed as a portable appliance and as detailed on page 3 it is instructed that the unit is to be wired to a means for disconnecting the fixed wiring in all poles in accordance with the wiring rules eg 13A fused double pole isolating switch In the unlikely event that the unit is fitted incorrectly the recommendation is if test is carried out with water in...

Page 3: ...urrent BS 7671 IEE Wiring Regulations and the Water Fittings Regulations Local regulations may apply in other countries The steam vent connection MUST BE MADE as required in these instructions A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules Check that the mains supply matches the electrical rating on the product The rating plate i...

Page 4: ... top edge of the unit Disconnect the neon light carefully unclipping it from the front cover 9 Maintenance Descaling Process To Drain the unit Turn off the water and electricity power supplies Turn on the tap on the front of the unit to drain the tank Unscrew and remove the tap and remove 4 fixing screws on outer cover Shield the electronic controller from possible water damage Carefully remove th...

Page 5: ... a MANUAL RESET SAFETY DEVICE which operates in a BOIL DRY situation and a MANUAL RESET THERMOSTAT for detecting excessive steam in the event of electronic controller failure or water solenoid valve failure Unless you are a qualified engineer DO NOT ATTEMPT to repair this unit yourself In the event of malfunction please contact our Technical Service Helpline on 0844 372 7766 WARNING SCALDING HOT W...

Page 6: ...The supply cable must be a minimum of 1 0mm 3 Core multi strand PVC insulated mains cable The terminal block will not accept cable diameters above 1 5mm Check that the mains supply matches the electrical rating on the product The rating plate is located on the bottom edge of the unit IMPORTANT Connect the supply cable complying with BS 6500 to this appliance in accordance with the following code G...

Reviews: