B. Condenser air is drawn in on the bottom of the unit and discharged out the rear of the unit. A
minimum of two (2) inches (5.08 cm) must be maintained between the back of the unit and the
wall.
Failure to maintain the proper clearance space will cause the compressor to overheat and
result in premature compressor failure.
1.4
CONNECTING TO WATER SUPPLY
A. Flush water supply line thoroughly.
B. Remove drip tray by pulling up slightly and away from unit. Remove dispensing paddles by
squeezing together at top and pull down.
C. Remove splash plate by pulling bottom up slightly and then out from unit.
D. Connect the inlet water shut off to water inlet fitting on bottom of unit using a flare seal washer.
Use a backup wrench to prevent damage to strainer.
E. Connect other end of the water tube assembly to water supply line using a flare seal washer.
Open valve on water supply and check for leaks.
F. Replace splash plate, drip tray and dispensing paddles.
1.5
FILLING UNIT WITH WATER
A. Remove both lids on top of unit.
B. Disconnect check valves (feed line) from top of concentrate containers and remove concentrate
container from unit.
C. Remove yellow plug from agitator deck.
D. Using a funnel or tube, fill with water until water flows out of overflow hole into concentrate
container compartment. Facing the front of the unit, the overflow hole is in the rear wall of the
concentrate container compartment. The overflow water will drain into the drip tray.
E. Replace yellow plug.
1.6
CONNECTING TO ELECTRICAL POWER
WARNING
THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL
ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS
PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED
ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE
UNIT.
Plug unit power cord into electrical outlet. Compressor and condenser fan motor will run until unit
builds a complete ice bank. Agitator motor will run continuously.
1.7
PURGING UNIT OF AIR
A. Raise front cover and turn key switch ON.
B. Using a cup, actuate each dispensing paddle until a steady flow of water is obtained.
C. Turn key switch OFF.
1.8
FILLING CONCENTRATE CONTAINER
A. Thoroughly clean concentrate containers in warm soapy water. Rinse well.
B. Fill each concentrate container with concentrate. Refer to Specifications (page iii) for capacity of
concentrate containers.
C. Replace concentrate containers in unit. Be sure they are properly located and seated all the
way down. Facing unit, each concentrate container
MUST
have filler tube and product sensors
to the front.
D. Replace check valves (yellow elbow) in concentrate containers using a rotating movement while
pushing down.
E. Replace both lids on top of unit.
1.9
PRIMING CONCENTRATE PUMPS
A. Turn key switch ON.
B. Press and hold the mode switch to the FLUSH position.
C. Hold cup under spout and depress the dispensing paddle until a solid flow of water is obtained
through the concentrate pump.
2
Summary of Contents for CENTURIONII 85-0055
Page 28: ...11 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 11 1 CENTURION II FINAL ASSEMBLY 24...
Page 30: ...26 11 2 CENTURION II PUMP REGULATOR ASSEMBLY...
Page 32: ...11 3 CENTURION II WATER CONCENTRATE COMPONENT ASSEMBLY 28...
Page 34: ...30 11 4 CENTURION II REFRIGERATION ASSEMBLY...