E. Remove the two (2) 0.110 inch FAST-ON connectors from the back of the mode switch.
F. Remove the securing nut from the back of the switch and push the switch through the front of
the control panel.
NOTE
This switch must be positioned so the spring return (momentary) position corresponds to the
FLUSH position.
G. Install the new switch in the reverse order.
H. Install the control panel (refer to Section 6.3).
6.6
CIRCUIT BREAKER REPLACEMENT
A. Remove the control panel (refer to Section 6.1).
B. Remove the control panel (refer to Section 6.2).
C. Remove the eight (8) screws securing the transformer and control PCB plate to the control
panel.
D. Disconnect the two (2) 0.250 inch FAST-ON connectors from the back of the circuit breaker.
E. Remove the retaining clip from the back of the circuit breaker.
F. Push the circuit breaker out of the front of the control panel.
H. Install in the reverse order.
I.
Install the control panel (refer to Section 6.3).
J. Turn key switch
ON
.
6.7
PADDLE SENSOR
A. Turn key switch
OFF
.
B. Remove dispensing paddles and drip tray.
C. Remove splash plate.
D. Unplug sensor from harness.
E. Loosen nut on back of sensor.
F. Remove sensor from bracket.
G. Replace with new sensor and adjust so that sensor face is about 1/8 inch (about 3.175 mm) from
the splash plate.
H. Replace splash plate.
I.
Replace dispensing paddles and drip tray.
J. Turn key switch
ON
.
NOTE
Sensors are sealed units and
cannot
be repaired. If the sensor is shorted (burned out), the PCB
will shut off automatically. When the sensor is replaced, the PCB will automatically reset.
6.8
CONCENTRATE PUMP
CAUTION
THE MOTOR IS A FACTORY SEALED UNIT AND IS NOT FIELD REPAIRABLE. ANY ATTEMPT
TO FIELD REPAIR WILL VOID WARRANTY.
A. Replacement
1. If concentrate pump
will
operate, depress FLUSH mode until a clear stream of water is
dispensed.
2. If concentrate pump
will not
operate, proceed to Step 3.
3. Turn key switch
OFF
.
4. Remove check valve from concentrate container by pulling up.
5. Remove spout by loosening nut (turn counter clockwise) and pulling spout down. Do
NOT
lose o-ring between spout and threaded adaptor.
6. Remove inlet elbow by pulling up.
7. Remove concentrate pump by pulling out of pump support.
8. Replace new concentrate pump by reversing above procedure.
9. Turn key switch
ON
.
10. Readjust
o
Brix (refer to Section 1.10.)