![lancer 4400 Series Operation Manual Download Page 24](http://html1.mh-extra.com/html/lancer/4400-series/4400-series_operation-manual_3484736024.webp)
IBD 4500/4600/LCD
24
TROUBLE
CAUSE
REMEDY
4.16
Valve will not shut off.
A. Debris in solenoid seat.
B. Solenoid plunger sticking.
A. Activate valve a few times to free
debris. Remove the solenoid coil
and plunger. Clean out any foreign
material.
B. Replace solenoid coil.
4.17
Syrup only dispensed.
No water, but CO2 gas
dispensed with syrup.
A. Improper water flow to dis-
penser.
B. Carbonator pump motor has
timed out (a message will
be displayed on the LCD
screen).
C. Liquid level probe not
connected properly to PCB.
D. Defective PCB assembly.
E. Defective liquid level probe.
F. Weak or defective carbonator
pump.
A. Check for water flow to
dis-
penser.
B. Reset by turning the unit
OFF
and then ON by using
the
circuit breaker on the
power supply or momentarily
unplugging unit.
C. Check connections of liquid level
probe to PCB assembly.
D. Replace PCB assembly.
E. Replace liquid level probe.
F. Replace pump.
4.18
Excessive foaming.
A. No ice in bin.
B. Incoming water or syrup
temperature too high.
C. CO2 pressure too high.
D. Water flow rate too high.
E. Nozzle and diffuser not clean.
F. Air in BIB lines.
A. Fill bin with ice and allow coldplate
to re-stabilize.
B. Correct prior to dispenser.
C. Adjust CO2 pressure
downward, but not less than 70
PSI.
D. Re-adjust and reset ratio.
E. Remove and clean.
F. Bleed air from BIB lines.
4.19
Water continually leaking
at connections.
A. Loose water connections.
B. Flare seal washer leaks.
A. Tighten water connections.
B. Replace flare seal washer.
CONTINUED ON NEXT PAGE
Summary of Contents for 4400 Series
Page 30: ...7 2 FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER 30 IBD 4500 4600 LCD...
Page 32: ...IBD 4500 4600 LCD 32 7 3 LCD UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Page 34: ...IBD 4500 4600 LCD 34 7 4 4600 NO COLD pLATE UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Page 41: ...7 8 WIRINg DIAgRAM 115v 60HZ 41 OPERATIONS AND SERVICE MANUAL PN 28 0255 11...
Page 42: ...IBD 4500 4600 LCD 42 7 9 WIRINg DIAgRAM 230v 50 60HZ...
Page 45: ...OPERATIONS AND SERVICE MANUAL PN 28 0255 11 7 13 IBD 22 COUNTER CUTOUT 45...
Page 46: ...7 14 IBD 30 COUNTER CUTOUT 46 IBD 4500 4600 LCD...