1.9 LCD INSTALLATION
If the monitor is not powered on, remove the merchandiser from the unit.
A. Remove the four (4) screws on the sides and lifting the merchandiser off and set aside.
B. Check that the power cable plug is pushed all the way in the bottom of the monitor.
C. Push the monitor power button on the bottom right side until the button is lit.
D. Replace the merchandiser and the 4 screws
E. Connect VGA cable with data source. Turn on data device
.
1.10 ADJUSTINg THE ICE FLOW REgULATOR FOR
OpTIONAL AFTERMARKET KIT 82-3949/012 (FIgURE 6)
The Regulator Door Assembly (PN 82-2904) can
regulate the dispensed ice flow. Installation of an
Ice Flow Regulator is NOT necessary for the
dispensing of ice. This IBD unit will dispense ice
unrestricted. If the monitor is not installed, remove LCD.
A. Remove Bin Lids.
B. Adjust Ice Regulator to desired position by
turning the nut screw clockwise to close, or
counter clockwise to open, with the use of a
nut driver or a socket wrench (Figure 6).
NOTE: Total adjustment: 1/2 inch.
C. Reinstall bin lids.
1.11 OTHER
Pouring hot water into drain may cause the drain
tube to collapse. Allow only luke warm or cold water
to enter the drain tube. Pouring coffee, tea, and
similar substances may cause clog the drain tube.
2. INSTALLATION OF vALvES (LMv,
LEV®
OR vOLUMETRIC)
2.1 Model 100
Valves are factory preset for a flow rate of 3.0 ounces per second; an adjustment may be
required.
2.2 Model 145
Factory preset for a flow rate of 4.5 ounces per second; an adjustment may be required.
2.3 Model 150
(Volumetric) Valves are preset for flows rates of 1.5 oz/sec, 2.25 oz/sec or 3.0 oz/sec based
on valve part number. A hand held programmer (Lancer PN 52-1420/02) is required to set
ratio on Volumetric Valves. Refer to Lancer web site (Installation Manuals 28-0027 for
LMV/LEV valves and 28-0301 for Volumetric valves) for information on the following:
Installation, Setting Flow Rate, Setting Ratio, Cleaning, Sanitizing, and Troubleshooting,
Turn Screw to Adjust
Adjustment
To Ice
ICE
CUT AWAY VIEW
Access Slot in
If necessary, bend
Wheel
Clockwise to Close
Counter Clockwise to Open
Plastic Wheel Shroud
slightly forward for
easier installation.
for adjustment
Use the access slot
Shroud
Dispensing Chute
SIDE
FIgURE 6
Summary of Contents for 4400 Series
Page 30: ...7 2 FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER 30 IBD 4500 4600 LCD...
Page 32: ...IBD 4500 4600 LCD 32 7 3 LCD UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Page 34: ...IBD 4500 4600 LCD 34 7 4 4600 NO COLD pLATE UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Page 41: ...7 8 WIRINg DIAgRAM 115v 60HZ 41 OPERATIONS AND SERVICE MANUAL PN 28 0255 11...
Page 42: ...IBD 4500 4600 LCD 42 7 9 WIRINg DIAgRAM 230v 50 60HZ...
Page 45: ...OPERATIONS AND SERVICE MANUAL PN 28 0255 11 7 13 IBD 22 COUNTER CUTOUT 45...
Page 46: ...7 14 IBD 30 COUNTER CUTOUT 46 IBD 4500 4600 LCD...