Lance-Larkin BREW EXPRESS BE-112 Installation Manual Download Page 8

5

.  Bring 1/4” 

water supply line

 from source (See page 6) 

 

to 

cut opening

 as shown in 

Figure 2

. (page 9).   

 

Bring water line through 

grommet 

in

 rough-in-box

  

 

(See 

Supply Detail

).  Carefully slide 

rough-In-box 

as  

 

shown into 

cut opening

 while gently pulling 

water supply line

  

 

through 

grommet

 hole in 

rough-in-box

 pulling through excess  

 

(approx. 18”).  Secure 

rough-in-box

 to wall stud with 

sheet rock 

 

screws

.  PURGE WATER LINE by running water through line to

 

 clean any possible debris.  Cut water line to length (approx. 3”)  

 

inside 

rough-in-box

 and attach 

male quick connector

.  

 

(See 

Male Connector Detail

) and 

Figure 4

.

IMPORTANT:
Water line to brewer must be flushed and a filter installed.  
Should debris clog brewer system  ALL WARRANTIES VOID.

4.

   Place 

rough-in-box 

on a towel or cardboard to protect  

counter surface.  Bring 

power supply wire

 from source  

to cut opening as previously shown in 

Figure 2.

 Minimum  

12-2 wire required.  Be sure to have an additional length of  
approximately 18” recommended at 

rough-in-box

 opening  

for installation of box.  Remove 

power panel cover.

  Install  

strain relief

 (not supplied) in hole. Run 

power supply wire

  

through 

strain relief 

and secure 

power supply wire

  

(See 

Supply Detail, page 10

). Connect 

power supply wires

 

 

to 

power panel supply wires

 and secure with 

wire nuts

 

 

(See 

Wiring Detail, page 10

). Connect 

green

 wire to 

 

green 

wire, 

black 

to 

black

 and 

white

 to 

white

.  Carefully 

 

reinstall 

power panel cover

. Be certain not to damage 

 

wires or insulation. 

See Figure 3.

11

12

BrEwEr INSTALLATION

BrEwEr INSTALLATION

6.

  After 

sheet rock screws

 are in place, gently bend appropriate

 

tabs (long or short depending on wall thickness such as tile

 

or granite) as shown on all other areas to finish securing

 

rough-in box

 to 

wall

.  Use pliers (if needed) to 

bend/crimp

 

 tabs

 firmly to 

wall

.  Gently slide excess water line back through  

grommet into wall cavity leaving top of connector a maximum of  
3” above bottom of rough-in box.  See 

Figure 5

. and 

Figure 6

.

Installation of Brewer

7.

   Quick connector is valved at rough-in-box so water can be  

turned on prior to connection to coffee maker. Place unit on  
a towel or cardboard to protect counter surface.  Place

 

BREW EXPRESS™

 directly in front of 

rough-in box

.  Use 

quick

 

connector 

to connect 

water supply line

 from 

BREW EXPRESS™

 

to 

water supply line

 from 

rough-in-box

 (See 

Quick Connect Detail

).

 

Snap connectors together firmly.  Turn on water,

 check for leaks

 prior

 

to final installation of 

BREW EXPRESS™

.  If leaking, turn off water,

 

tighten connections or reinstall 

quick connector

.  Turn water on

 

and check again.  See 

Figure 7

.

8.  Gently slide the BREW EXPRESS™ into the rough-in-box.
 

Be careful not to damage water supply lines.  A firm fit will

 

connect power from rough-in-box to the BREW EXPRESS™. 

 

Use four mounting screws to secure BREW EXPRESS™

 

inside rough-in-box.  Be careful not to damage counter top.

 

NOTE: Refer to OPERATION GUIDE for further instructions

 

before using BREW EXPRESS™.

WARNING:
Do not caulk or grout brewer to wall.

3" max

Figure 6

Quick Connect Detail

Figure 7

Figure 8

Figure 5

Supply Detail

Wiring Detail

Male Connector Detail

All electrical wires and connections MUST be tucked 
neatly and completely inside POWER PANEL COVER 
without any exposed wiring inside rough-in box. It is  
advised you contact a qualified electrician.

Figure 4

Summary of Contents for BREW EXPRESS BE-112

Page 1: ...2 BREW EXPRESS INSTALLATION GUIDE model no BE 112 by For more information see our instructional video online at wwww BrewExpress com...

Page 2: ...2 2 Getting Started 3 3 Hardware Tools 4 4 Specification and Requirements 5 5 Location area of Installation 6 6 Water Installation 7 7 Power Installation 8 8 Brewer Installation 9 12 9 Testing 13 10...

Page 3: ...afety IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed including the following 1 Read all Instructions 2 Do not touch hot surfaces Use handles o...

Page 4: ...ain relief Romex wire clamp 1 4 Poly or copper line refrigerator ice maker kit continuous length recommended 12 2 wire per local code Caulking Gun Silicone Caulk Safety Glasses AC Power Sensor Crescen...

Page 5: ...ype filter can easily be installed at the source If water lines are not purged or clear of debris or a filter is NOT installed foreign particles debris in water may clog brewer system causing failure...

Page 6: ...net maker and building contractor for exact height of counter top due to the various thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are...

Page 7: ...ious thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are installed A Installing BREW EXPRESS on Counter It is best to install the unit s...

Page 8: ...ws are in place gently bend appropriate tabs long or short depending on wall thickness such as tile or granite as shown on all other areas to finish securing rough in box to wall Use pliers if needed...

Page 9: ...iring is incorrect Turn off power Remove power panel cover two screws and check wire source connection Check wire connection at source Water does not flow from spray head If the BREW EXPRESS has not b...

Page 10: ...will not keep coffee hot as long as the inner wall of carafe is heated by incoming coffee fluid Pre heat carafe for better and longer performance of a half pot Check supply voltage is maybe is too lo...

Page 11: ...Printed in CHINA BE112 IG 02_07 R 1 LANCE LARKIN 2005 www brewexpress com...