TrOUBLESHOOTING
Water overflow from brew basket
•
Paper filter is not high enough and grounds are flowing over and plugging brew basket (use higher filter)
We suggest purchasing Bunn Brand Filters.
Excessive Steam
•
Inlet water line connected to hot water supply (connect to cold water).
•
Water pressure is too low, below 30 psi (increase water pressure).
•
Spray head is plugged (remove spray head, and clean or replace).
•
Water flow is too low, confirm by running a full carafe and checking volume. If water level in carafe is low,
call for technical service.
Taste Not Acceptable
•
Quality or Quantity of coffee is not high enough (purchase better quality coffee)
•
Spray head is plugged and water is boring hole in grounds (clean or replace spray head)
•
Check temperature inside of a full carafe of water. It is possible heater is not working properly or thermostat
sensor is not working properly.
•
Check volume of water on a full carafe setting. If it is overfilling and temperature is wrong, call for technical service.
Brewer turning on and off during cycle
•
The brewer turns on and off the heater to control the water temperature. The amount depends on many factors
(inlet water temperature, water flow rate, heat wattage, supply voltage).
•
Excessive on and off will also result in excessive steam. See excessive steam for more information.
•
Clicking noise: This is temperature control and it is normal operation.
•
Brewing light flashing: IRD problem.
Water temperature cold or luke warm
•
Carafe not keeping coffee hot long enough. Consider if you are brewing a full pot or half pot. Half pot will not keep
coffee hot as long as the inner wall of carafe is heated by incoming coffee fluid. Pre-heat carafe for better and longer
performance of a half pot.
•
Check supply voltage is maybe is too low, below low 115 VAC (increase supply voltage).
•
Water flow rate too high, confirm by running 2-3 pots of water first then call for technical service.
•
Heater failed, call for technical service.
•
Internal electrical connection failed, call for technical service.
Carafe or Mug not detected (flashing brew light)
•
IRD cannot detect flat black or clear glass mug (change mug color)
•
IRD window is dirty (wipe with moist towel and dry)
•
Mug not close enough to IRD (move farther into brewer)
•
IRD is not set properly, call for technical service.
Water dripping from spray head
•
Spray head plugged (replace or clean spray head)
•
Normally, some water will drip from the spray head shortly after brewing
•
Slight valve leak (debris inside valve, disconnect water and reconnect, run 1-2 full cycles of water in carafe to
dislodge debris and check)
•
Valve leak permanent, call for technical service.
Water dripping down walls of carafe area
•
Spray head plugged (replace or clean spray head)
•
Spray head leak around threads, (remove spray head, clean and re-install for tight fit)
Coffee not staying warm
•
Possible carafe vacuum failure (if carafe is warm to touch, replace carafe)
•
Preheat carafe before brewing coffee especially if used for half pot. (run brew cycle without filter or coffee)
•
Check volume of water by running a full cycle of water without coffee. If carafe overfills call for technical service.
•
Check voltage to coffee maker.
Water leak from back of brewer
•
Check quick connect (push connectors together firmly and slightly twist)
•
Poly line leak at brewer, call installer to repair.
•