Installation of Rough-In-Box

1.

  Locate 

wall studs

 within the desired location of 

wall

.

 

Using the 

template

 provided, Place 

template

 on 

wall

 as

 

shown.  

Slots

 in 

template

 should be flush with left or right

 

side of 

wall stud

 edge. The 

slots

 in the 

template

 designate

 

the area to be cut.  The bottom of 

template

 reflects the

 

bottom of the unit.  

See figure 1.

2. 

  Use a utility knife to carefully cut inside the penciled 

 

outline area.  Start with the stud side and work outward. 

 

DO NOT USE A SAW.  Remove sheet rock piece exposing 

 

wall cavity

. Bring 

water

 and 

power supply

 lines from source 

 

to this location. 

See Figure 2.

3. 

  Completely seal all gaps between counter and wall with 

 

silicone caulk. This prevents water from going behind the

 

cabinet if there is a water leak.

Figure 3

Figure 1

9

10

BrEwEr INSTALLATION

BrEwEr INSTALLATION

IMPORTANT:
If installing Unit PRIOR to cabinets, it is strongly advised to consult with cabinet maker and build-
ing contractor for exact height of counter top due to the various thicknesses of counter tops (tile 
laminate, granite, etc).  For best results cut hole and install unit AFTER cabinets are installed.

A.  Installing BREW EXPRESS™ on Counter

 

It is best to install the unit so the bottom edge is just off the

 

counter top.  In an existing home, this may require part of the

 

back splash to be removed.  Use 

template 

provided to

 

determine the location to be cut out for rough-in-box.

B.  Installing BREW EXPRESS™ with Full Back Splash
 

 

Use 

template

 provided to determine the location to be cut

 

out for rough-in-box.  Ensure fit is correct by first placing

 

 rough-in-box in cut out hole.  Remove rough-in-box.  Finish  
installation of full height back splash to cut opening.  If full  
height back splash is granite or tile, it is recommended to  
cut opening and install rough-in-box after surface is complete. 

 

IMPORTANT:

 DO NOT COMPLETE INSTALLATION OF

 

ROUGH-IN-BOX BEFORE BACK SPLASH.

C.  Installing BREW EXPRESS™ above Back Splash
 

 

If you prefer a continuous back splash, the unit can be installed

 

above the back splash.  Use 

template

 provided to find best fit.

 

IMPORTANT:

 WHEN INSTALLING THE UNIT ABOVE BACK

 

SPLASH, BE CERTAIN THERE IS SUFFICIENT ROOM BELOW

 

THE CABINETS.

Caulk gap

Figure 2

Summary of Contents for BREW EXPRESS BE-112

Page 1: ...2 BREW EXPRESS INSTALLATION GUIDE model no BE 112 by For more information see our instructional video online at wwww BrewExpress com...

Page 2: ...2 2 Getting Started 3 3 Hardware Tools 4 4 Specification and Requirements 5 5 Location area of Installation 6 6 Water Installation 7 7 Power Installation 8 8 Brewer Installation 9 12 9 Testing 13 10...

Page 3: ...afety IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed including the following 1 Read all Instructions 2 Do not touch hot surfaces Use handles o...

Page 4: ...ain relief Romex wire clamp 1 4 Poly or copper line refrigerator ice maker kit continuous length recommended 12 2 wire per local code Caulking Gun Silicone Caulk Safety Glasses AC Power Sensor Crescen...

Page 5: ...ype filter can easily be installed at the source If water lines are not purged or clear of debris or a filter is NOT installed foreign particles debris in water may clog brewer system causing failure...

Page 6: ...net maker and building contractor for exact height of counter top due to the various thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are...

Page 7: ...ious thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are installed A Installing BREW EXPRESS on Counter It is best to install the unit s...

Page 8: ...ws are in place gently bend appropriate tabs long or short depending on wall thickness such as tile or granite as shown on all other areas to finish securing rough in box to wall Use pliers if needed...

Page 9: ...iring is incorrect Turn off power Remove power panel cover two screws and check wire source connection Check wire connection at source Water does not flow from spray head If the BREW EXPRESS has not b...

Page 10: ...will not keep coffee hot as long as the inner wall of carafe is heated by incoming coffee fluid Pre heat carafe for better and longer performance of a half pot Check supply voltage is maybe is too lo...

Page 11: ...Printed in CHINA BE112 IG 02_07 R 1 LANCE LARKIN 2005 www brewexpress com...