Lance-Larkin BREW EXPRESS BE-112 Installation Manual Download Page 3

IMPORTANT:
Read and follow instructions carefully before installing your BREW EXPRESS™ in-the-wall
COFFEE SYSTEM. Wire the BREW EXPRESS™ to a GFCI ground protected source.  
This can be accomplished by:

(A). Wiring the unit directly to a string of outlets that are protected by a GFCI outlet. OR

(B). Wiring the unit with a dedicated line to electrical panel with a GFCI breaker.

FOR BEST RESULTS ITS ADVISED THAT YOU HIRE A QUALIFIED PROFESSIONAL.

Always turn off all power at main electrical panel before attempting to install BREW EXPRESS™.   
Improper electrical wiring could cause a fire hazard.  All wiring MUST be performed in accordance with  
local electrical codes. Installation must be performed by a Qualified Electrician only, or equivalent.

Always turn off water supply at source when installing BREW EXPRESS™.  Improper installation of water supply
could cause poor performance or leaks which may lead to dry rot and cause structure damage to building.
Be certain water supply is leak free.  Hire a qualified plumber if necessary.

The BREW EXPRESS™ dispenses extremely hot water.  Hot liquids may cause severe burns if it contacts skin.
Use extreme caution when handling hot liquids dispensed by the BREW EXPRESS™.  KEEP HANDS AWAY
FROM SPRAY HEAD, BREW BASKET, CARAFE OR MUG DURING BREW CYCLE.  This product is intended
for brewing hot water for beverages only, and may not be used in any other way.

Check distance between wall cavity studs to ensure BREW EXPRESS™ will fit in desired location.   
Normal cavity is 14.5” wide and 4” deep.  Hire a qualified professional if necessary.

1

2

SAfETy

SAfETy 

IMPORTANT SAFEGUARDS

When using electrical appliances, basic safety precautions should always be followed, including the following:

 

1. Read all Instructions. 

 

2. Do not touch hot surfaces. Use handles or knobs.

 

3. The voltage and frequency of the supply connections should conform to those of the rating label.

 

4. Close supervision is necessary when any appliance is used by or near children.

 

5. Allow to cool before putting on or taking off parts, and before cleaning the appliance.

 

6. Do not operate any appliance after the appliance malfunctions, or has been damaged in any manner. 

 

    Return appliance to the nearest authorized service facility for examination, repair or adjustment.

 

7. The use of accessory attachments not recommended by the appliance manufacturer may result in fire, 

 

    electric shock or injury to persons.

 

8. Do not use outdoors.

 

9. Check specifications on page 4 for proper water pressure requirements of this product, or no less than 30 psi.

 

10. Do not place on or near a hot gas or electric burner, or in a heated oven.

 

11. The appliance should be installed in a place not easily reached by children.

 

12. Do not use appliance for other than intended use.

 

13. To reduce the risk of shock, discontinue use of the appliance if water leakage occurs.

 
 

14. The convenience receptacle provided is rated maximum 15 A.  Disconnect appliances when not in use.

 
 

15. To reduce the risk of fire, do not place any heating or cooking appliance beneath the appliance.

 

16. To reduce the risk of fire, do not mount unit over or near any portion of a heating or cooking appliance.

 

17. To reduce the risk of electric shock, do not mount over a sink.

 

18. To reduce the risk of fire, do not store anything directly on top of the appliance surface when the appliance 

 

      is in operation.

SAVE THESE INSTRUCTIONS

Summary of Contents for BREW EXPRESS BE-112

Page 1: ...2 BREW EXPRESS INSTALLATION GUIDE model no BE 112 by For more information see our instructional video online at wwww BrewExpress com...

Page 2: ...2 2 Getting Started 3 3 Hardware Tools 4 4 Specification and Requirements 5 5 Location area of Installation 6 6 Water Installation 7 7 Power Installation 8 8 Brewer Installation 9 12 9 Testing 13 10...

Page 3: ...afety IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed including the following 1 Read all Instructions 2 Do not touch hot surfaces Use handles o...

Page 4: ...ain relief Romex wire clamp 1 4 Poly or copper line refrigerator ice maker kit continuous length recommended 12 2 wire per local code Caulking Gun Silicone Caulk Safety Glasses AC Power Sensor Crescen...

Page 5: ...ype filter can easily be installed at the source If water lines are not purged or clear of debris or a filter is NOT installed foreign particles debris in water may clog brewer system causing failure...

Page 6: ...net maker and building contractor for exact height of counter top due to the various thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are...

Page 7: ...ious thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are installed A Installing BREW EXPRESS on Counter It is best to install the unit s...

Page 8: ...ws are in place gently bend appropriate tabs long or short depending on wall thickness such as tile or granite as shown on all other areas to finish securing rough in box to wall Use pliers if needed...

Page 9: ...iring is incorrect Turn off power Remove power panel cover two screws and check wire source connection Check wire connection at source Water does not flow from spray head If the BREW EXPRESS has not b...

Page 10: ...will not keep coffee hot as long as the inner wall of carafe is heated by incoming coffee fluid Pre heat carafe for better and longer performance of a half pot Check supply voltage is maybe is too lo...

Page 11: ...Printed in CHINA BE112 IG 02_07 R 1 LANCE LARKIN 2005 www brewexpress com...