Lance-Larkin BREW EXPRESS BE-112 Installation Manual Download Page 5

IMPORTANT:
Read and follow instructions carefully before installing your BREW EXPRESS™ in-the-wall  
COFFEE SYSTEM. For best results it is advised that you hire a qualified professional.

1.  Overall Dimensions

 (Finished Unit with Rough-in-Box) approximately 12.5” x 12.5” (see below).

2.  Dimensions for Rough-in-Box

 (Mounting Structure) approximately 11.5” x 11.5” x 4”.

 

3.  Electrical Requirements

 120VAC, 60HZ. (1400 watts).

4.  Water Requirements

 1/4” OD water supply line (copper or poly) minimum 30 psi to a maximum of

 

90 psi.  Potable COLD water is required.

 

NOTE:  If water is not available, an alternate water dispenser jug (5 gallons) can be used with the

 

optional pump accessory (not supplied).  Contact dealer for more information.

Please Note:  A filter and shut off valve at water source is required.
 

The filter such as an ice maker type filter, can easily be installed at the source. 

 

If water lines are not purged or clear of debris or a filter is NOT installed, foreign

 

particles (debris) in water may clog brewer system causing failure, and may

 

void all warranties.

6

SpECIfICATIONS AND rEqUIrEmENTS

LOCATION 

(Area of Installation)

AREA ON WALL 

TO BE CUT 

(USE TEMPLATE) 

11

-1/2" 

(292.1mm) 

3 1/4" (83.0 mm)

The BREW EXPRESS™ can be installed in most places where power and water are supplied.  If only power is available,
you may consider using water jug alternative.  The most common locations are the kitchen, master bathroom, or office.

Installation in an exterior wall is not recommended due to risk of water freezing. See warranty section for 
additional information.

NOTE:  It is important to check stud width and location for proper fit.  Minimum width and depth requirements for rough-in-
box are 11.5" x 11.5" x 4".  Please use template provided for proper fit for your location.

IDEAL LOCATION AREAS

A. On Counter

B. Full Height Back Splash

C. Above Back splash

5

Summary of Contents for BREW EXPRESS BE-112

Page 1: ...2 BREW EXPRESS INSTALLATION GUIDE model no BE 112 by For more information see our instructional video online at wwww BrewExpress com...

Page 2: ...2 2 Getting Started 3 3 Hardware Tools 4 4 Specification and Requirements 5 5 Location area of Installation 6 6 Water Installation 7 7 Power Installation 8 8 Brewer Installation 9 12 9 Testing 13 10...

Page 3: ...afety IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed including the following 1 Read all Instructions 2 Do not touch hot surfaces Use handles o...

Page 4: ...ain relief Romex wire clamp 1 4 Poly or copper line refrigerator ice maker kit continuous length recommended 12 2 wire per local code Caulking Gun Silicone Caulk Safety Glasses AC Power Sensor Crescen...

Page 5: ...ype filter can easily be installed at the source If water lines are not purged or clear of debris or a filter is NOT installed foreign particles debris in water may clog brewer system causing failure...

Page 6: ...net maker and building contractor for exact height of counter top due to the various thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are...

Page 7: ...ious thicknesses of counter tops tile laminate granite etc For best results cut hole and install unit AFTER cabinets are installed A Installing BREW EXPRESS on Counter It is best to install the unit s...

Page 8: ...ws are in place gently bend appropriate tabs long or short depending on wall thickness such as tile or granite as shown on all other areas to finish securing rough in box to wall Use pliers if needed...

Page 9: ...iring is incorrect Turn off power Remove power panel cover two screws and check wire source connection Check wire connection at source Water does not flow from spray head If the BREW EXPRESS has not b...

Page 10: ...will not keep coffee hot as long as the inner wall of carafe is heated by incoming coffee fluid Pre heat carafe for better and longer performance of a half pot Check supply voltage is maybe is too lo...

Page 11: ...Printed in CHINA BE112 IG 02_07 R 1 LANCE LARKIN 2005 www brewexpress com...

Reviews: