1. Place the system where you want to install it, making 

sure it is on a clean, level and firm base.

2. Add Minerals: Remove control valve from the mineral 

tank by turning counterclockwise. Plug open end (top) of 

distributor tube to prevent any mineral from entering. Add 

mineral to top chamber of the tank. 

DO NOT OVERFILL

There must be at least 10” of space between the top of 

the tank and the mineral. Remove the plug from the top 

of  the  distributor  tube.  If  mineral  used  is  carbon,  water 

can be manually added to the tank to begin the soaking 

process. Carbon should be soaked for a 24-hour period 

to prevent the carbon from floating and being lost to drain 

during backwash. Replace control valve.

3. Do all necessary plumbing (inlet to inlet, outlet to outlet, 

and drain line to drain). The control valve, fittings and/or 

bypass  are  designed  to  accommodate  minor  plumbing 

misalignments but are not designed to support the weight 

of a system or the plumbing.

4. When assembling the installation fitting package (inlet 

and  outlet),  connect  the  fitting  to  the  plumbing  system 

first  and  then  attach  the  nut,  split  ring  and  o-ring.  Heat 

from soldering or solvent cements may damage the nut, 

split ring or o-ring. Solder joint should be cool and solvent 

cements should be set before installing the nut, split ring 

and  o-ring. Avoid  getting  primer  and  solvent  cement  on 

any part of the o-rings, split rings, bypass valve or control 

valve.

5. A jumper ground wire should be installed between 

the  inlet  and  outlet  pipe  whenever  the  metallic 

continuity  of  a  water  distribution  piping  system  is 

interrupted. Install grounding strap on metal pipes.

6. The drain connection may be made using either 5/8” 

polytube  (see  page  6)  or  a  3/4”  female  adapter.  The 

polytube  insert  is  shipped  attached  to  the  drain  line 

elbow’s  locking  clip.  Press  the  insert  into  the  drain  line 

tubing (tubing not provided). Loosen the nut of the drain 

line  elbow.  Press  the  5/8”  polytube  with  insert  into  the 

drain  line  elbow  until  it  seats  on  the  back  of  the  fitting. 

Tighten the nut. If soldering, joints near the drain must be 

done prior to connecting the drain line flow control fitting. 

Leave at least 6” between the drain line control fitting and 

solder joints when soldering pipes that are connected on 

the drain line control fitting. Failure to do this could cause 

interior damage to the drain line flow control fitting. Never 

insert a drain line into a drain, sewer line, or trap. Always 

allow an air gap between the drain line and the wastewater 

to prevent the possibility of sewage being back-siphoned 

into the system.

7. The brine refill flow control assembly is installed in an 

easy to access refill elbow located on top of the control 

valve. The refill flow control assembly is attached to the 

control valve with a locking clip. The locking clip allows the 

elbow to rotate 270 degrees so the outlet can be oriented 

towards the brine tank.

8. Connect the brine line polytubing found with the brine 

tank  to  the  brine  connection  on  the  control  valve.  The 

control valve has a standard refill elbow to which a 3/8” 

flexible tube can be connected, see

 

page 6. One polytube 

insert  is  shipped  on  the  brine  line  elbow’s  locking  clip. 

Remove this white polytube insert and replace the locking 

clip.  The  second  polytube  insert  is  taped  to  the  top  of 

the brine well cap in the brine tank. Press the polytube 

inserts into each end of the provided brine tubing, press 

the polytube with insert into the nut on the brine fitting. 

Tighten nut securely to create a pressure tight connection. 

The  nut,  gripper  and  retainer  sleeve  is  a  three-piece 

assembly  that  can  come  apart  from  the  elbow  body. 

Parts must be reassembled exactly as shown to function 

properly. If the nut is completely removed from the body, 

slip the nut, plastic gripper and retainer sleeve on to the 

tube  then  tighten  on  to  the  fitting.  Make  sure  the  floor 

is  clean  beneath  the  brine  tank  and  that  it  is  level  and 

smooth.  Install  brine  tubing  to  the  brine  tank  using  the 

above instructions.

9. A 1/2” (inside diameter, not provided) gravity drain line 

should be connected to the overflow fitting on the side of 

the brine tank. This overflow is in case of a malfunction in 

the brine shut off. If the unit is installed where water may 

flow in the event of an overflow and cause water damage, 

connect a length of flexible tubing and run to a drain below 

the level of the overflow. 

(Do not connect the tubing to 

the drain line on the control valve. Do not run tubing 

above overflow height at any point.)

(All electrical & plumbing should be done in accordance to all local codes)

INSTALLATION INSTRUCTIONS

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Summary of Contents for City Soft Plus XFactor Series

Page 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Page 2: ...Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review...

Page 3: ...r treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WATER...

Page 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Page 5: ...pes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting Never insert a drain line into a drain sewer line or trap...

Page 6: ...WITH BRINE TANK OVERFLOW GRAVITY DRAIN ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF DO NOT CONNECT TO CONTROL VALVE DRAIN LINE IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE CO...

Page 7: ...least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the br...

Page 8: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Page 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Page 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Page 11: ...SDCS 1 A8056 Centaur Carbon for chloramine reduction in 7 LESDCS 1 6 A4074 3 4 Cu Ft 39 LBS Ion Exchange Resin for Model 7 LXD 75 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LXD 100 1 A4074...

Page 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Page 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Page 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Page 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Page 16: ...2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various position...

Page 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Page 18: ...are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears t...

Page 19: ...embly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible throu...

Page 20: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Page 21: ...eter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See...

Page 22: ...possible increase pump switch cut in to 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restrictions or debris...

Page 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Main drive gear too tight c Loosen main...

Page 24: ...reconnect c MAV NHBP motor not fully engaged with reduction gears c Properly insert motor into casing do not force into casing Press NEXT and REGEN buttons for 3 seconds to resynchronize software wit...

Page 25: ...PAGE 25 NOTES...

Page 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 4 14...

Reviews: