background image

 

 

For models

 T../MA-BTB

,

 T../MA-BTBC 

and 

T../MA-ANJ 

 
 
 
 
 
 
 
 
 
 

 

INSTALLER’S MANUAL 

 

THIS  MANUAL  IS  TO  BE  LEFT  WITH  THE  OWNER  OF  THE  EQUIPMENT  FOR  REFERENCE 

PURPOSES  AND  TECHNICAL  GUIDANCE.  IT  IS  STRONGLY  RECOMMENDED  THAT  QUALIFIED 

DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION 

OF  SERVICE  OR  APPARENT  PRODUCT  MALFUNCTION.  AN  ANNUAL  PREVENTATIVE 

MAINTENANCE  INSPECTION  BY  A  WATER  PROFESSIONAL  IS  RECOMMENDED  TO  ENSURE 

TROUBLE-FREE AND CONTINUOUS OPERATION. 

 

R1 

Summary of Contents for T../MA-ANJ series

Page 1: ...CE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE FREE AND CONTINUOUS OPERATION R1 ...

Page 2: ...n which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times salt dose exchange capacity and gallon capacity regeneration time A salt warning option may also be included THE DEALER 1 Read this page GENERAL INSTRUCTIONS INSTALLER SETTINGS NORMAL OPERATING DISPLAYS and LOW SALT WARNING 2 Complete the CYCLE SEQUENCE SETTINGS 3 ...

Page 3: ...ough them When moving through any displays or programmings if no buttons are pressed within five minutes the display returns to normal operating displays Any changes made prior to the five minute time out are incorporated To quickly exit any programming Installer Settings etc press CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible w...

Page 4: ...p 5CS Press UP or DOWN until FILL appears Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Press UP or DOWN until END appears Press NEXT to exit Cycle Sequence Press REGEN to return to previous step SOFTENER SYSTEM SETUP In SOFTENER SYSTEM SETUP you choose the time for the cycles selected in CYCLE SEQUENCE and specifies other operating parameters for the system The uppe...

Page 5: ...ess as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time The grains capacity for the selected fill time should be confirmed by testing The capacity and hardness levels entered are used to automatically calculate reserve capacity when capacity is set to AUTO...

Page 6: ...of no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Press NEXT until SALT LEVEL MONITOR appears Set Salt LEVEL MONITOR using UP or DOWN If the value is set to OFF no low salt level warning will appear for the user A specific value ALERT will flash on the display when the cal...

Page 7: ...ion water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolated from the water pressure in the plumbing system Untreated water is supplied to the building See Figure 2 3 Diagnostic Position The inlet handle points toward the control valve and the outlet handle ...

Page 8: ...ssure relief valve Also be certain that local codes are not violated 4 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to room temperatures under 34 F 49 C 5 The use of resin cleaners in an unvented enclosure is not recommended SERIAL NUMBER Record the serial number on the installer s and customer s records INLET OUTLET PLUMBING Connect ...

Page 9: ...s allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into the conditioner INSTALLER SETTINGS Step 1I Press NEXT and UP simultaneously for 3 seconds Step 2I Hardness Set the amount of hardness in grains of hardness as calcium carbonate per gallon using DOWN or UP The default is 20 with value ranges from 1 to 150 in 1 grain increments ...

Page 10: ...il the error or alert is reset by the user Press NEXT to exit Installer Display Setting Press REGEN to return to the previous step SET TIME OF DAY Time of day should only need to be set if the battery has been depleted because of extended power outages or when daylight saving time begins or ends If an extended power outage occurs the time of day will flash on and off which indicates the time of da...

Page 11: ...emaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heav...

Page 12: ...BACKWASH and the remaining time is counting down Unplug transformer to prevent valve from moving to the next cycle 3 Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media 4 When the water is flowing steadily to the drain without the presence of air restore power and momen...

Page 13: ...12 REPLACEMENT PARTS ...

Page 14: ...13 REPLACEMENT PARTS ...

Page 15: ...14 REPLACEMENT PARTS ...

Page 16: ...15 REPLACEMENT PARTS ...

Page 17: ...16 REPLACEMENT PARTS ...

Page 18: ...17 INSTALLATION FITTING ASSEMBLIES ...

Page 19: ...force on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner Pressing to the left helps the drive gears mesh with the drive cap assembly The drive bracket is properly seated when it snaps under the latches on the drive back plate If resistance is felt before latching then notches are not fully engaged the piston rod is not in...

Page 20: ...nt may be used on black o rings but is not necessary Avoid any type of lubricants including silicone on red or clear lip seals Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the drive cap bottoms out Excessive force can break the notches molded into t...

Page 21: ...sing dilute sodium bisulfite or vinegar Do not use a wire brush If necessary replace the flow control flow control retainer o ring or the elbow o ring Reseat the flow control so the rounded end with lettering is visible in the flow control retainer Reseat the white flow control retainer by inserting the retainer into the elbow until the o ring seats Remove locking clip insert elbow into valve body...

Page 22: ...otating the assembly as you pull it out will enable it to be removed more easily There are three o rings one under the rotor cap one on the rotor stem and one on the rotor seal Replace worn o rings Clean rotor Reinstall rotor Before reinstalling the red arrow handles be sure that o rings on both rotors face to the right when being viewed from the front when the handle pointers are pointing in the ...

Page 23: ... assy d Piston not in home position d Press NEXT and REGEN or momentarily unplug PC board power e Motor gears not fully engaged Motor wires broken Failed motor e Check motor and wiring f Center drive gear reflector dirty or damaged Missing or broken gear f Replace or clean drive gear s g Drive bracket incorrectly aligned on back plate g Reset drive bracket h PC board is damaged or defective h Repl...

Page 24: ...23 Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204 783 1599 fax www waterite com ...

Reviews: