background image

PAGE 7

7

TROUBLESHOOTING

Figure 10

Figure 11

Figure 12

Figure 13

Figure 14

Figure 15

Figure 16

Figure 17

POWER ON, PUMP ON and FAILURE
lights all off. Tap opened, no
pressure boost, pump off (Fig.10).

Power supply is on but no lights are lit.

Turn off power supply to the Mascontrol and

remove the electronic box cover. Check all

electrical connections to be certain they are

tightly fastened to the proper terminals for

the voltage needed (115V or 230V).

Refer to the schematic in the electronic box.

If all electrical connections are secure and

correct, test electrical terminals with meter

to ensure power is present at all

terminals. If power is at the terminals, the

electronic box has failed and must be

replaced (power must be on to unit to test

terminals).

POWER ON and FAILURE light on,
PUMP ON light is off. Tap opened,
no pressure boost, pump off (Fig.11)

The unit has detected one of the following:

1. Loss of suction - check water supply.

2. Blockage in pipe from water supply to

pump and Mascontrol - remove blockage.

3. If a pump has a thermal protection

switch, check to make sure the switch has

not been tripped by the pump. If pump has

been switched off due to the thermal switch,

check pump for proper operation and 

condition and reset thermal switch. Press

restart button on Mascontrol. Pump should

start up.

4. The pump capacitor has failed or is not

adequate.

5. Electronic box failed - replace box (rare

occurrence).

POWER ON and FAILURE light on,
PUMP ON light is off. Tap closed,
pump off (Fig.12).

1. Pump cannot attain at least 55 psi

(incoming psi + boost) at close-off - 

check pump pressure reading with pressure

gauge. Pump must be able to attain at least

55 psi to work properly with Mascontrol unit.

2. Electronic box failure - replace box (rare

occurrence).

POWER ON, PUMP ON and FAILURE
lights are all on. Tap opened, no
pressure boost, pump off (Fig.13).

The tap is open and the pump is not

operating. Check the wiring in the electronic

box to make sure all wires are securely 

fastened to the proper terminals.

Also recheck voltage for correct application

(115V or 230V). Press the restart button.

If all lights remain on and the pump still

does not operate, the electronic box has

failed and should be replaced.

POWER ON, PUMP ON and FAILURE
lights are all on. Tap closed, pump
on (Fig.14).

The pump is operating and all taps are

closed, the electronic box has failed and

must be replaced.

POWER ON light on, FAILURE light
off and PUMP ON light short cycles
on and off. Tap closed, pump cycles
on and off (Fig.15).

1. Leakage less than 0.21 gpm may be 

present in piping. The higher the leakage

rate (but less than 0.21 gpm) the faster the

pump cycles. Make sure all taps are closed

and all toilet valves are functioning properly.

After tap inspection check all piping and

valves connected to the system for leakage.

To help determine leak location, close the

shut-off valve after the Mascontrol. If pump 

cycling stops, leak is located after the Mas-

control in the water supply. Shut off power to

Mascontrol and locate and fix leak. Restore

power to Mascontrol (Mascontrol will start

the pump automatically) and monitor system

to determine that leak has been corrected.

2. If pump cycling still occurs after closing

the shut-off valve behind Mascontrol, the

bottom check valve is obstructed from 

closing properly.

POWER ON and PUMP ON light on,
FAILURE light off. All taps closed,
pump runs continuously (Fig.16).

1. The condition may be similar to

condition 1 (Fig.15) above but leak flow rate 

is greater than 0.21 gpm. In this case the 

leak simulates an open tap condition.

Follow instructions for condition 1,

figure 15 above.

2. The top flow valve to the Mascontrol is

obstructed.

3. The electronic box has failed and should

be replaced.

POWER ON light on, PUMP ON and
FAILURE light off. Tap open,
no flow or no pressure boost,

The column of water between Mascontrol

and the highest tap exceeds 70 feet, 

therefore the column of water has created

a pressure higher than the cut-in pressure

of Mascontrol (32 psi). This prevents the

unit from working properly. Reposition

Mascontrol higher so the water column

height is less than 70 feet.

Low

PSI

Low

PSI

Low

PSI

pump off (Fig.17).

Summary of Contents for CITY BOSS

Page 1: ...mp is a SAFE psi for the application s piping and fixtures If required a pressure reducing valve can be installed in line after the booster system to reduce water pressure to a safe level A pressure relief valve piped to a suitable drain is recommended for overall system protection Never install or service the pump or system without relieving the internal pressure 2 WARNING HAZARDOUS VOLTAGE Volta...

Page 2: ...ngs on the inlet side of pump and discharge side of pump controller for ease of disconnecting booster system for service or to protect from freezing ELECTRICAL CONNECTIONS Wiring to this booster system must be installed and maintained in accordance with both the National Electrical Code and state local codes Make sure motor voltage rating matches available power supply See the motor nameplate Dual...

Page 3: ...tecting leakage in the service piping greater than 0 21 GPM the value of the minimum flow below which the flow switch stops the booster pump MASCONTROL will protect the booster pump from damage if the city supply piping to the booster pump inlet is dry or blocked MASCONTROL will detect irregular city water supply conditions and shut off the booster pump The red Failure light will be on After the p...

Page 4: ...unting MASCONTROL pump controller see Figure 1 The MASCONTROL may be mounted directly on the booster pump s outlet MASCONTROL must be mounted on a vertical column with the electronic box level and the flow direction arrows pointing upward Use only Teflon tape for threaded connections Do not install any tap between the pump and the MASCONTROL Detailed system installation diagram see Figure 2 Relief...

Page 5: ... wiring diagrams Replace MASCONTROL s electronic box cover using the six screws upon completion of wiring the system If cover is not securely fastened RESTART button will not operate Figure 3A 115VAC Single Phase Wiring Diagram Figure 3B 230VAC Single Phase Wiring Diagram 8 Position Terminal Block MASCONTROL Model 8 Position Terminal Block MASCONTROL Model Figure 4 115VAC or 230VAC Single Phase Wi...

Page 6: ...lled and ready to operate automatically Using the RESTART Button If water does not enter the pump and MASCONTROL the red FAILURE light will illuminate and the MASCONTROL will shut off the pump within 20 30 seconds This is the run dry protection feature preventing damage to the pumps internal components See Figure 9 After the water supply problem is corrected is a check valve installed backwards di...

Page 7: ...astened to the proper terminals Also recheck voltage for correct application 115V or 230V Press the restart button If all lights remain on and the pump still does not operate the electronic box has failed and should be replaced POWER ON PUMP ON and FAILURE lights are all on Tap closed pump on Fig 14 The pump is operating and all taps are closed the electronic box has failed and must be replaced PO...

Page 8: ...PAGE 8 A DIVISION OF C B TOOL 1340 Manheim Pike Lancaster PA 17601 3196 Tel 717 397 3521 Fax 717 392 0266 www lancasterpump com ...

Reviews: